Door Lock

Inspection

~16min read

INSPECTION

PROCEDURE

1. INSPECT FRONT LH DOOR LOCK ASSEMBLY WITH MOTOR (without double locking system)

(a) Check the operation of the door lock motor (for driver side).

(1) Apply battery voltage to the motor connector and check the operation of the door lock motor.

OK:

Measurement Condition

Specified Condition

Battery positive (+) → 4 (L)

Battery negative (-) → 1 (UL)

Lock

Battery positive (+) → 1 (UL)

Battery negative (-) → 4 (L)

Unlock

Battery positive (+) → 9 (L)

Battery negative (-) → 10 (UL)

ON

Battery positive (+) → 10 (UL)

Battery negative (-) → 9 (L)

OFF

HINT:

  • Move the door lock motor to the lock position and activate the double locking system. Make sure the doors cannot be unlocked using the control cable.
  • Move the door lock motor to the lock position and deactivate the double locking system. Make sure the doors can be unlocked using the control cable.

If the result is not as specified, replace the front LH door lock assembly with motor.

*a

Component part without wire harness connected (front LH door lock assembly with motor)

*b

Unlock

*c

Lock

(b) Check the operation of the door unlock detection switch and the double locking position switch (for driver side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

8 (LSSR) - 7 (E)

Lock

10 kΩ minimum

8 (LSSR) - 7 (E)

Unlock

Below 1 Ω

9 (L) - 10 (UL)

OFF

10 kΩ minimum

9 (L) - 10 (UL)

ON

Below 1 Ω

If the result is not as specified, replace the front LH door lock assembly with motor.

(c) Check the resistance of the lock and unlock switch (for driver side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

9 (L) - 7 (E)

Held in lock position

Below 1 Ω

9 (L) - 7 (E)

Held in neutral or unlock position

10 kΩ minimum

10 (UL) - 7 (E)

Held in unlock position

Below 1 Ω

10 (UL) - 7 (E)

Held in neutral or lock position

10 kΩ minimum

If the result is not as specified, replace the front LH door lock assembly with motor.

*a

Component part without wire harness connected (front LH door lock assembly with motor)

*b

Unlock

*c

OFF

*d

Lock

(d) Check the operation of the door lock motor (for front passenger side).

(1) Apply battery voltage to the motor connector and check the operation of the door lock motor.

OK:

Measurement Condition

Specified Condition

Battery positive (+) → 4 (L)

Battery negative (-) → 1 (UL)

Lock

Battery positive (+) → 1 (UL)

Battery negative (-) → 4 (L)

Unlock

If the result is not as specified, replace the front LH door lock assembly with motor.

*a

Component part without wire harness connected (front LH door lock assembly with motor)

*b

Unlock

*c

Lock

(e) Check the operation of the door unlock detection switch (for front passenger side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

8 (LSSR) - 7 (E)

Lock

10 kΩ minimum

8 (LSSR) - 7 (E)

Unlock

Below 1 Ω

If the result is not as specified, replace the front LH door lock assembly with motor.

2. INSPECT FRONT RH DOOR LOCK ASSEMBLY WITH MOTOR (without double locking system)

(a) Check the operation of the door lock motor (for front passenger side).

(1) Apply battery voltage to the motor connector and check the operation of the door lock motor.

OK:

Battery connection

Specified Condition

Battery positive (+) → 4 (L)

Battery negative (-) → 1 (UL)

Lock

Battery positive (+) → 1 (UL)

Battery negative (-) → 4 (L)

Unlock

If the result is not as specified, replace the front RH door lock assembly with motor.

*a

Component part without wire harness connected (front RH door lock assembly with motor)

*b

Unlock

*c

Lock

(b) Check the operation of the door unlock detection switch (for front passenger side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

7 (LSSR) - 8 (E)

Lock

10 kΩ minimum

7 (LSSR) - 8 (E)

Unlock

Below 1 Ω

If the result is not as specified, replace the front RH door lock assembly with motor.

(c) Check the operation of the door lock motor (for driver side).

(1) Apply battery voltage to the motor connector and check the operation of the door lock motor.

OK:

Measurement Condition

Specified Condition

Battery positive (+) → 4 (L)

Battery negative (-) → 1 (UL)

Lock

Battery positive (+) → 1 (UL)

Battery negative (-) → 4 (L)

Unlock

Battery positive (+) → 6 (L)

Battery negative (-) → 5 (UL)

ON

Battery positive (+) → 5 (UL)

Battery negative (-) → 6 (L)

OFF

HINT:

  • Move the door lock motor to the lock position and activate the double locking system. Make sure the doors cannot be unlocked using the control cable.
  • Move the door lock motor to the lock position and deactivate the double locking system. Make sure the doors can be unlocked using the control cable.

If the result is not as specified, replace the front RH door lock assembly with motor.

*a

Component part without wire harness connected (front RH door lock assembly with motor)

*b

Unlock

*c

Lock

(d) Check the operation of the door unlock detection switch and the double lock position switch (for driver side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

7 (LSSR) - 8 (E)

Lock

10 kΩ minimum

7 (LSSR) - 8 (E)

Unlock

Below 1 Ω

5 (UL) - 6 (L)

OFF

10 kΩ minimum

5 (UL) - 6 (L)

ON

Below 1 Ω

If the result is not as specified, replace the front RH door lock assembly with motor.

(e) Check the resistance of the lock and unlock switch (for driver side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

6 (L) - 8 (E)

Held in lock position

Below 1 Ω

6 (L) - 8 (E)

Held in neutral or unlock position

10 kΩ minimum

5 (UL) - 8 (E)

Held in unlock position

Below 1 Ω

5 (UL) - 8 (E)

Held in neutral or lock position

10 kΩ minimum

If the result is not as specified, replace the front RH door lock assembly with motor.

*a

Component part without wire harness connected (front RH door lock assembly with motor)

*b

Unlock

*c

OFF

*d

Lock

3. INSPECT FRONT DOOR LH LOCK ASSEMBLY WITH MOTOR (with double lock system)

(a) Check the operation of the door lock motor (for driver side).

(1) Apply battery voltage and check the operation of the front door lock motor and the double lock motor.

OK:

Measurement Condition

Specified Condition

Battery positive (+) → 4 (L)

Battery negative (-) → 3 (UL)

Lock

Battery positive (+) → 3 (UL)

Battery negative (-) → 4 (L)

Unlock

Battery positive (+) → 2 (DL)

Battery negative (-) → 1 (UNDL)

ON

Battery positive (+) → 1 (UNDL)

Battery negative (-) → 2 (DL)

OFF

HINT:

  • Move the door lock motor to the lock position and activate the double locking system. Make sure the doors cannot be unlocked using the control cable.
  • Move the door lock motor to the lock position and deactivate the double locking system. Make sure the doors can be unlocked using the control cable.

If the result is not as specified, replace the front LH door lock assembly with motor.

*a

Component part without wire harness connected (front LH door lock assembly with motor)

*b

Unlock

*c

Lock

(b) Check the operation of the door unlock detection switch and the double locking position switch (for driver side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

8 (LSSR) - 7 (E)

Lock

10 kΩ minimum

8 (LSSR) - 7 (E)

Unlock

Below 1 Ω

6 (DLSR) - 5 (E)

OFF

10 kΩ minimum

6 (DLSR) - 5 (E)

ON

Below 1 Ω

If the result is not as specified, replace the front LH door lock assembly with motor.

(c) Check the resistance of the lock and unlock switch (for driver side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

9 (L) - 7 (E)

Held in lock position

Below 1 Ω

9 (L) - 7 (E)

Held in neutral or unlock position

10 kΩ minimum

10 (UL) - 7 (E)

Held in unlock position

Below 1 Ω

10 (UL) - 7 (E)

Held in neutral or lock position

10 kΩ minimum

If the result is not as specified, replace the front LH door lock assembly with motor.

*a

Component part without wire harness connected (front LH door lock assembly with motor)

*b

Lock

*c

Unlock

(d) Check the operation of the door lock motor (for front passenger side).

(1) Apply battery voltage to the motor connector and check the operation of the door lock motor.

OK:

Measurement Condition

Specified Condition

Battery positive (+) → 4 (L)

Battery negative (-) → 3 (UL)

Lock

Battery positive (+) → 3 (UL)

Battery negative (-) → 4 (L)

Unlock

Battery positive (+) → 2 (DL)

Battery negative (-) → 1 (UNDL)

ON

Battery positive (+) → 1 (UNDL)

Battery negative (-) → 2 (DL)

OFF

HINT:

  • Move the door lock motor to the lock position and activate the double locking system. Make sure the doors cannot be unlocked using the control cable.
  • Move the door lock motor to the lock position and deactivate the double locking system. Make sure the doors can be unlocked using the control cable.

If the result is not as specified, replace the front LH door lock assembly with motor.

*a

Component part without wire harness connected (front LH door lock assembly with motor)

*b

Unlock

*c

Lock

(e) Check the operation of the door unlock detection switch and the double lock position switch (for front passenger side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

8 (LSSR) - 7 (E)

Lock

10 kΩ minimum

8 (LSSR) - 7 (E)

Unlock

Below 1 Ω

6 (DLSR) - 5 (E)

OFF

10 kΩ minimum

6 (DLSR) - 5 (E)

ON

Below 1 Ω

If the result is not as specified, replace the front LH door lock assembly with motor.

4. INSPECT FRONT DOOR RH LOCK ASSEMBLY WITH MOTOR (with double lock system)

(a) Check the operation of the front door lock motor (for front passenger side).

(1) Apply battery voltage and check the operation of the front door lock motor and the double lock motor.

OK:

Measurement Condition

Specified Condition

Battery positive (+) → 2 (L)

Battery negative (-) → 1 (UL)

Lock

Battery positive (+) → 1 (UL)

Battery negative (-) → 2 (L)

Unlock

Battery positive (+) → 4 (DL)

Battery negative (-) → 3 (UNDL)

ON

Battery positive (+) → 3 (UNDL)

Battery negative (-) → 4 (DL)

OFF

HINT:

  • Move the door lock motor to the lock position and activate the double locking system. Make sure the doors cannot be unlocked using the control cable.
  • Move the door lock motor to the lock position and deactivate the double locking system. Make sure the doors can be unlocked using the control cable.

If the result is not as specified, replace the front RH door lock assembly with motor.

*a

Component part without wire harness connected (front RH door lock assembly with motor)

*b

Unlock

*c

Lock

(b) Check the operation of the door unlock detection switch and the double lock position switch (for front passenger side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

7 (LSSR) - 8 (E)

Lock

10 kΩ minimum

7 (LSSR) - 8 (E)

Unlock

Below 1 Ω

9 (DLSR) - 10 (E)

OFF

10 kΩ minimum

9 (DLSR) - 10 (E)

ON

Below 1 Ω

If the result is not as specified, replace the front RH door lock assembly with motor.

(c) Check the operation of the front door lock motor (for driver side).

(1) Apply battery voltage and check the operation of the front door lock motor and the double lock motor.

OK:

Battery connection

Result

Battery positive (+) → 2 (L)

Battery negative (-) → 1 (UL)

Lock

Battery positive (+) → 1 (UL)

Battery positive (+) → 2 (L)

Unlock

Battery positive (+) → 4 (DL)

Battery negative (-) → 3 (UNDL)

ON

Battery positive (+) → 3 (UNDL)

Battery negative (-) → 4 (DL)

OFF

HINT:

  • Move the door lock motor to the lock position and activate the double locking system. Make sure the doors cannot be unlocked using the control cable.
  • Move the door lock motor to the lock position and deactivate the double locking system. Make sure the doors can be unlocked using the control cable.

If the result is not as specified, replace the front RH door lock assembly with motor.

*a

Component part without wire harness connected (front RH door lock assembly with motor)

*b

Unlock

*c

Lock

(d) Check the operation of the door unlock detection switch and the double lock position switch (for driver side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

7 (LSSR) - 8 (E)

Lock

10 kΩ minimum

7 (LSSR) - 8 (E)

Unlock

Below 1 Ω

9 (DLSR) - 10 (E)

OFF

10 kΩ minimum

9 (DLSR) - 10 (E)

ON

Below 1 Ω

If the result is not as specified, replace the front RH door lock assembly with motor.

(e) Check the operation of the door lock and unlock key switch (for driver side).

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

6 (L) - 8 (E)

Held in lock position

Below 1 Ω

6 (L) - 8 (E)

Held in neutral or unlock position

10 kΩ minimum

5 (UL) - 8 (E)

Held in unlock position

Below 1 Ω

5 (UL) - 8 (E)

Held in neutral or lock position

10 kΩ minimum

If the result is not as specified, replace the front RH door lock assembly with motor.

*a

Component part without wire harness connected (front RH door lock assembly with motor)

*b

Lock

*c

Unlock