K114 Continuously Variable Transmission

Inspection

~3min read

INSPECTION

PROCEDURE

1. INSPECT TRANSMISSION SPEED SENSOR (NIN)

*a

Component without wire harness connected

(Transmission Speed Sensor (NIN))

(a) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

1 (NIN-) - 2 (NIN+)

20 °C

560 à 680 Ω

If the result is not as specified, replace the transmission speed sensor (NIN).

2. INSPECT TRANSMISSION SPEED SENSOR (NOUT)

(a) Connect the battery to the transmission speed sensor (NOUT) as shown in the illustration.

(b) Swing a magnetic object left and right in front of the end of the transmission speed sensor (NOUT) (clearance of 5 mm (0.197 in.) max.) to change the low/high signals while measuring the current.

NOTICE:

Be sure to swing a magnetic object during the inspection. The current will not change without swinging the magnetic object as indicated by the arrow in the illustration.

*1

Battery

*a

Component without wire harness connected

(Transmission Speed Sensor (NOUT))

*b

Magnet

*c

Clearance of 5 mm (0.197 in.) max.

*d

Ammeter

(c) Measure the current according to the value(s) in the table below.

Standard current:

Tester Connection

Condition

Specified Condition

1 (NOTO) - 2 (NOTB)

Low signal

4 to 8 mA

High signal

12 to 16 mA

If the result is not as specified, replace the transaxle speed sensor (NOUT).

3. INSPECT TRANSMISSION SPEED SENSOR (NT)

(a) Connect the battery to the transmission speed sensor (NT) as shown in the illustration.

(b) Oscillate a magnetic object left and right in front of the end of the transmission speed sensor (NT) (maximum clearance of 5 mm (0.197 in.)) to change the low/high signals while measuring the current.

NOTICE:

Be sure to swing a magnetic object during the inspection. The current will not change without swinging the magnetic object as indicated by the arrow in the illustration.

*1

Battery

*a

Component without wire harness connected

(Transmission Speed Sensor (NT))

*b

Magnet

*c

Clearance of 5 mm (0.197 in.) max.

*d

Ammeter

(c) Measure the current according to the value(s) in the table below.

Standard current:

Tester Connection

Condition

Specified Condition

1 (NTO) - 2 (NTB)

Low signal

4 to 8 mA

High signal

12 to 16 mA

If the result is not as specified, replace the transmission speed sensor (NT).