K114 Continuously Variable Transmission

Inspection

~1min read

INSPECTION

PROCEDURE

1. INSPECT PARK/NEUTRAL POSITION SWITCH

*a

Component without wire harness connected

(park/neutral position switch)

(a) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

4 (B) - 9 (L)

Shift lever in P or N

Below 1 Ω

Shift lever in position other than P or N

10 kΩ minimum

1 (RB) - 3 (PL)

Shift lever in P position

Below 1 Ω

Shift lever in position other than P

10 kΩ minimum

1 (RB) - 2 (RL)

Shift lever in R position

Below 1 Ω

Shift lever in position other than R

10 kΩ minimum

1 (RB) - 8 (NL)

Shift lever in N

Below 1 Ω

Shift lever in position other than N

10 kΩ minimum

1 (RB) - 7 (DL)

Shift lever in D or M

Below 1 Ω

Shift lever in position other than D or M

10 kΩ minimum

If the result is not as specified, replace the park/neutral position switch.