Cooling is Poor
DESCRIPTION
If the cooling effect of the air conditioning system is weak, the following factors may be the cause.
Symptom | Factor |
|---|---|
|
|
PROCEDURE
PERFORM REFRIGERANT SHORTAGE CHECK
(a) Perform the Utility according to the display on the GTS.
Body Electrical > Air Conditioner > UtilityRefrigerant Gas Volume Check
(b) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.
Measurement Condition:Item | Condition |
|---|---|
A/C switch |
On |
Ambient temperature* |
0 to 49 °C |
Blower speed |
HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
Result | Amount of Refrigerant |
|---|---|
Refrigerant correct |
Correct |
Refrigerant shortage |
Insufficient |
OK:
"Refrigerant correct" is displayed on the GTS.
| NG | REPAIR REFRIGERANT LEAK |
|
PERFORM ACTIVE TEST USING GTS
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active TestTester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
Front Air Mix Damper Control Servo Motor |
No. 1 air conditioning radiator damper servo sub-assembly pulse |
Min.: 128 Max.: 384 |
Operate with ignition switch ON. |
Front Air Mix Damper Control Servo Motor
Front Air Mix Damper Control Servo Motor Actual Pulse
OK:
The No. 1 air conditioning radiator damper servo motor operates.
| OK | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
| NG | GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR |