No Cool Air Comes Out
DESCRIPTION
If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.
Symptom | Factor |
|---|---|
No cool air comes out
|
|
PROCEDURE
CHECK SWITCH INDICATOR
(a) Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.
OK:
All switch indicators operate normally.
| NG | GO TO OTHER DIAGNOSIS PROCEDURE (Operation not Accepted Even If Air Conditioning Switch is Operated) |
|
PERFORM ACTIVE TEST USING GTS
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active TestTester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
Front Air Mix Damper Control Servo Motor |
No. 1 air conditioning radiator damper servo sub-assembly pulse |
Min.: 128 Max.: 384 |
- |
Front Air Mix Damper Control Servo Motor
Front Air Mix Damper Control Servo Motor Actual Pulse
OK:
The No. 1 air conditioning radiator damper servo motor operates.
| OK | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
| NG | GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR |