Customize Parameters
CUSTOMIZE PARAMETERS
CUSTOMIZE AIR CONDITIONING SYSTEM
(a) Customizing with the GTS.
NOTICE:
- When the customer requests a change in a function, first make sure that the function can be customized.
- Be sure to make a note of the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
HINT:
The following items can be customized.
(1) Select the setting by referring to the table below.
Air ConditionerTester Display | Description | Default | Setting | ECU |
|---|---|---|---|---|
Fan Speed Increment Control |
Function to set the speed to reach the target blower fan speed when AUTO mode is on |
Normal |
$01:Short,$00:Normal,$02:Long |
Air conditioning amplifier assembly |
Outside Air Mode Auto Switch Function |
Function to automatically change the air inlet to FRESH mode when the ignition switch is off for 60 seconds |
ON |
$00:OFF,$01:ON |
Air conditioning amplifier assembly |
Evaporator Control |
Function to set the evaporator control to the automatic position (Automatic) to save power or to the coldest position (Manual) to dehumidify the air and to prevent the windows from fogging up |
Automatic |
$00:Manual,$01:Automatic |
Air conditioning amplifier assembly |
Refrigerant Shortage Check |
Function to cancel the refrigerant shortage check (check performed during normal operation) when set to ON |
ON |
$00:OFF,$01:ON |
Air conditioning amplifier assembly |
Ambient Temperature Adjustment |
Function to control with the shifted ambient temperature against the display ambient temperature |
ON |
$04:-3C,$05:-2C,$06:-1C,$00:Normal,$01:+1C,$02:+2C,$03:+3C |
Air conditioning amplifier assembly |