Front Window Fogging
DESCRIPTION
If the windshield frequently fogs up even though the air conditioning system is operating, the following factors may be the cause.
Symptom | Factor |
|---|---|
Windshield frequently fogs up |
|
PROCEDURE
PERFORM REFRIGERANT SHORTAGE CHECK
(a) Perform the Utility according to the display on the GTS.
Body Electrical > Air Conditioner > UtilityRefrigerant Gas Volume Check
(b) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.
Measurement Condition:Item | Condition |
|---|---|
A/C switch |
On |
Ambient temperature* |
0 to 49 °C |
Blower speed |
HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
Result | Amount of Refrigerant |
|---|---|
Refrigerant correct |
Correct |
Refrigerant shortage |
Insufficient |
OK:
"Refrigerant correct" is displayed on the GTS.
| NG | CHARGE SYSTEM WITH REFRIGERANT |
|
CHECK OPERATION
(a) Press the front defroster switch on the air conditioning control assembly and check that the air outlet mode changes to DEF mode.
OK:
The air outlet mode changes to DEF mode.
| OK | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
| NG | GO TO DTC B14037F |