Recirculated/Fresh Air Modes do not Switch
DESCRIPTION
If the air inlet mode cannot be changed between recirculation/fresh or exhaust gas odors can be smelled even though recirculation mode is selected, the following factors may be the cause.
Symptom | Factor |
|---|---|
|
|
PROCEDURE
CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
(a) Check that the No. 1 blower damper servo sub-assembly is installed correctly.
OK:
The No. 1 blower damper servo sub-assembly is installed correctly.
| NG | INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY |
|
CHECK FOR DTC
(a) Check for DTCs.
Body Electrical > Air Conditioner > Trouble CodesResult | Proceed to |
|---|---|
B143A87 and B143B7F is not output |
A |
B143A87 is output |
B |
B143B7F is output |
C |
| B | GO TO DTC B143A87 |
| C | GO TO DTC B143B7F |
|
READ VALUE USING GTS
(a) Read the Data List according to the display on the GTS.
Powertrain > Engine > Data ListTester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Coolant Temperature |
Engine coolant temperature |
Min.: -40°C (-40°F), Max.: 140 °C |
75 to 100 °C: After warming up |
This is the engine coolant temperature. HINT:
|
Coolant Temperature
OK:
After warming up the engine, the temperature value displayed is within the range specified in the normal condition column.
| OK | REPLACE AIR CONDITIONER UNIT ASSEMBLY |
| NG | GO TO COOLING SYSTEM |