Some relays are built into the integration relay. The integration relay cannot be disassembled. If there is a malfunction in the circuit of the integration relay, replace the integration relay.
The internal circuit of the integration relay is as shown in the illustration below. Inspect the integration relay using the following procedures.
(a) Measure the resistance of the A/F fuse.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
A/F fuse
Always
Below 1 Ω
If the result is not as specified, replace the A/F fuse.
(b) Measure the resistance of the A/F sensor heater relay.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
1C-1 - 1A-4
When battery voltage is not applied to terminals 1A-2 and 1A-3
10 kΩ or higher
When battery voltage is applied to terminals 1A-2 and 1A-3
Below 1 Ω
If the result is not as specified, replace the integration relay.