Inspection
1. INSPECT INTEGRATION RELAY
(a) Inner circuit (for 2GR-FE)
(1) for EFI MAIN relay
Standard Resistance:
HINT: If the result is not as specified, replace the integration relay. |
![]() |
(2) for A/F relay
Standard Resistance:
HINT: If the result is not as specified, replace the integration relay. |
![]() |
(3) for F/PMP relay (for AWD)
Standard Resistance:
HINT: If the result is not as specified, replace the integration relay. |
![]() |
(4) for C/OPN relay
Standard Resistance:
HINT: If the result is not as specified, replace the integration relay. |
![]() |
(5) for HORN relay
Standard Voltage:
HINT: If the result is not as specified, replace the integration relay. |
![]() |
(6) for H-LP LO (LH) relay
- Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
1D-1 - Body ground |
Battery positive (+) - 1A-1 Battery negative (-) - 1F-17 |
11 to 14 V |
1A-1 - 1D-1 |
Always |
Below 1 V |
*1 |
Component without harness connected (Integration Relay) |
HINT:
If the result is not as specified, replace the integration relay.
(7) for H-LP LO (RH) relay
- Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
1D-2 - Body ground |
Battery positive (+) - 1A-1 Battery negative (-) - 1F-17 |
11 to 14 V |
1A-1 - 1D-2 |
Always |
Below 1 V |
*1 |
Component without harness connected (Integration Relay) |
HINT:
If the result is not as specified, replace the integration relay.
(8) for H-LP HI (DRL) relay
- for Halogen headlight
- Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Condition
Specified Condition
1A-1 - 1D-3
Always
Below 1 V
1A-1 - 1D-4
Always
Below 1 V
1F-15 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
11 to 14 V
1F-15 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
Pulse generation
1F-16 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
11 to 14 V
1F-16 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
Pulse generation
- Measure the voltage according to the value(s) in the table below.
- for HID headlight
- Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Condition
Specified Condition
1A-1 - 1D-3
Always
Below 1 V
1A-1 - 1D-4
Always
Below 1 V
1F-15 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
Pulse generation
1F-16 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
Pulse generation
- Measure the voltage according to the value(s) in the table below.
*1 |
Component without harness connected (Integration Relay) |
HINT:
If the result is not as specified, replace the integration relay.
(b) Inner circuit (for 1AR-FE)
(1) for EFI MAIN No. 2 relay
Standard Resistance:
HINT: If the result is not as specified, replace the integration relay. |
![]() |
(2) for EFI MAIN relay
Standard Resistance:
HINT: If the result is not as specified, replace the integration relay. |
![]() |
(3) for C/OPN relay
Standard Resistance:
HINT: If the result is not as specified, replace the integration relay. |
![]() |
(4) for HORN relay
Standard Voltage:
HINT: If the result is not as specified, replace the integration relay. |
![]() |
(5) for H-LP LO (LH) relay
- Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
1D-1 - Body ground |
Battery positive (+) - 1A-1 Battery negative (-) - 1F-17 |
11 to 14 V |
1A-1 - 1D-1 |
Always |
Below 1 V |
*1 |
Component without harness connected (Integration Relay) |
HINT:
If the result is not as specified, replace the integration relay.
(6) for H-LP LO (RH) relay
- Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
1D-2 - Body ground |
Battery positive (+) - 1A-1 Battery negative (-) - 1F-17 |
11 to 14 V |
1A-1 - 1D-2 |
Always |
Below 1 V |
*1 |
Component without harness connected (Integration Relay) |
HINT:
If the result is not as specified, replace the integration relay.
(7) for H-LP HI (DRL) relay
- for Halogen headlight
- Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Condition
Specified Condition
1A-1 - 1D-3
Always
Below 1 V
1A-1 - 1D-4
Always
Below 1 V
1F-15 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
11 to 14 V
1F-15 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
Pulse generation
1F-16 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
11 to 14 V
1F-16 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
Pulse generation
- Measure the voltage according to the value(s) in the table below.
- for HID headlight
- Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Condition
Specified Condition
1A-1 - 1D-3
Always
Below 1 V
1A-1 - 1D-4
Always
Below 1 V
1F-15 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
Pulse generation
1F-16 - Body ground
Battery positive (+) - 1A-1
Battery negative (-) - 1F-15
Battery negative (-) - 1F-16
Pulse generation
- Measure the voltage according to the value(s) in the table below.
*1 |
Component without harness connected (Integration Relay) |
HINT:
If the result is not as specified, replace the integration relay.