Heating, Ventilation, and Air Conditioning
Mode Control Actuator Repair Procedures
In this manual: Heating, Ventilation, and Air Conditioning
17steps
~102min
4/5difficulty
Done 0 of 17
Inspection
- Ignition switch OFF
- Disconnect the mode actuator connector.
- Make sure the mode control actuator operates in the defrost mode when 12 V is applied to terminal 3 and terminal 7 is grounded.
- Check that the mode actuator operates in the vent mode when the polarity is reversed.
1. -
2. -
3. Defrost mode
4. Sensor ground5. Feedback signal
6. 5 V (DC)
7. Vent mode - Check the voltage between terminals 4 and 5. Specification
Door Position Voltage (4-5) Fault Detection Max. Cool 0.3 ± 0.15 V Low voltage: 0.1 V or less Max. Heat 4.7 ± 0.15 V High voltage: 4.9 V or more
It transmits the current position of the actuator to the control unit. - If the measured voltage does not meet the specification, replace the mode actuator with a known good actuator and check for proper operation.
- If the problem is resolved, replace the mode actuator.
Replacement
- Disconnect the negative (-) battery terminal.
- Remove the left side airbag cover (A).
- Remove the console side cover [LH]. (Refer to Group BD - "Console")
- Remove the lower emergency air bag cover (A) by loosening the mounting screws.
- Disconnect the diagnostic connector (A) and remove the lower air bag cover.
- Remove the left shower duct (A).
- Remove the BCM (A) by loosening the mounting bolt and nut.
- Disconnect the mode control actuator connector (A).
- Loosen the mounting screw and remove the mode control actuator (B).
- Installation is the reverse of removal.
Test yourself
A quick Kia Cadenza VG Owner's Manual quiz: every answer comes with an explanation and a link to the manual page.
Was this page helpful?