Engine Control System/Fuel System

Repair Procedures - Purge Control Solenoid Valve (PCSV)

8steps
~48min
2/5difficulty
0102030405011.89N·mlb·ft
Tightening torque found on this page
Done 0 of 8

Inspection

  1. Turn the ignition off.
  2. Disconnect the PCSV connector.
  3. Measure the resistance between terminals 1 and 2 of the PCSV.
  4. Make sure the resistance is within specification.

    Specification: 19.0 ~ 22.0 [20 °C]

Removal

  1. Turn the ignition switch OFF and disconnect the negative (-) battery terminal.
  2. Disconnect the purge control solenoid valve connector (A).
  3. Disconnect the vapor hoses (B) from the purge control solenoid valve.
  4. Remove the valve from the bracket in the direction indicated by the arrow.

Installation

  • Install the component with the specified torque.
  • Note that internal damage may occur if the component is dropped. If the component has been dropped, inspect it before installation.
  • Take care not to allow foreign matter to enter the valve.
  • Install the purge control solenoid valve by fitting the support pin (A) into the bracket.
  1. Install in the reverse order of removal. Purge control solenoid valve bracket bolt: 9.8 ~ 11.8 N·m

Test yourself

A quick Kia Optima Hybrid Owner's Manual quiz: every answer comes with an explanation and a link to the manual page.