Engine Control System/Fuel System
Repair Procedures - Purge Control Solenoid Valve (PCSV)
In this manual: Engine Control System/Fuel System
8steps
~48min
2/5difficulty
Done 0 of 8
Inspection
- Turn the ignition off.
- Disconnect the PCSV connector.
- Measure the resistance between terminals 1 and 2 of the PCSV.
- Make sure the resistance is within specification.
Specification: 19.0 ~ 22.0 [20 °C]
Removal
- Turn the ignition switch OFF and disconnect the negative (-) battery terminal.
- Disconnect the purge control solenoid valve connector (A).
- Disconnect the vapor hoses (B) from the purge control solenoid valve.
- Remove the valve from the bracket in the direction indicated by the arrow.
Installation
|
- Install in the reverse order of removal. Purge control solenoid valve bracket bolt: 9.8 ~ 11.8 N·m
Test yourself
A quick Kia Optima Hybrid Owner's Manual quiz: every answer comes with an explanation and a link to the manual page.
Was this page helpful?