Component Function Check

CHECK INTERIOR ROOM LAMP POWER SUPPLY FUNCTION

CONSULT

  1. Ignition switch ON.

  2. Turn each interior room lamp ON.

    • Personal lamp 2nd row LH

    • Personal lamp 2nd row RH

    • Front room/map lamp assembly

    • Luggage room lamp

    • Vanity lamp LH

    • Vanity lamp RH

  3. Select “BATTERY SAVER” in “Active Test” mode of “BCM(BATTERY SAVER)”.

  4. While operating the test items, check that each interior room lamp turns ON/OFF.

    Off : Interior room lamp ON
    On : Interior room lamp OFF

Does the interior room lamp turn ON/OFF?

YES>>

Interior room lamp power supply circuit is normal.

NO>>

Refer to Diagnosis Procedure.

Diagnosis Procedure

CHECK INTERIOR ROOM LAMP POWER SUPPLY OUTPUT

CONSULT

  1. Ignition switch OFF.

  2. Disconnect the following connectors:

    • Personal lamp 2nd row LH

    • Personal lamp 2nd row RH

    • Front room/map lamp assembly

    • Luggage room lamp

    • Vanity lamp LH

    • Vanity lamp RH

    • Automatic back door close switch

  3. Ignition switch ON.

  4. Select “BATTERY SAVER” in “Active Test” mode of “BCM(BATTERY SAVER)”.

  5. While operating the test item, check voltage between BCM harness connector and ground.

BCM(–)Test item

Voltage

(Approx.)
(+)
ConnectorTerminal
M81 129 Ground BATTERY SAVER Off Battery voltage
On 0 V

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Battery voltage exists and remains unchanged: GO TO 2.

NO>>

Battery voltage does not exist and remains unchanged: GO TO 3.

CHECK INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT SHORT TO POWER

  1. Ignition switch OFF.

  2. Disconnect the BCM connector.

  3. Check voltage between BCM harness connector and ground.

BCM—

Voltage

(Approx.)
ConnectorTerminal
M81 129 Ground 0 V

Is the inspection result normal?

YES>>

Replace BCM. Refer to Removal and Installation.

NO>>

Repair or replace harnesses.

CHECK INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT SHORT TO GROUND

  1. Ignition switch OFF.

  2. Disconnect the BCM connector.

  3. Check continuity between BCM harness connector and ground.

BCM—Continuity
ConnectorTerminal
M81 129 Ground No

Is the inspection result normal?

YES>>

Replace BCM. Refer to Removal and Installation.

NO>>

Repair or replace harnesses.

CHECK INTERIOR ROOM LAMP POWER SUPPLY OPEN CIRCUIT

  1. Ignition switch OFF.

  2. Disconnect the BCM connector.

  3. Check continuity between BCM harness connector and each interior room lamp harness connector.

BCMEach interior room lampContinuity
ConnectorTerminalConnectorTerminal
M81 129 Front room/map lamp assembly R6 8 Yes
Luggage room lamp B26 1
Vanity lamp LH R14
Vanity lamp RH R10
Personal lamp 2nd row LH R16
Personal lamp 2nd row RH R17

Is the inspection result normal?

YES>>

Check intermittent incident. Refer to Intermittent Incident.

NO>>

Repair or replace harnesses.