Driver Controls

Interior Room Lamp Control Circuit

15steps
~90min
4/5difficulty
Done 0 of 15
Component Function Check
  • Battery saver output/power supply circuit

  • Front room/map lamp assembly

  • Personal lamps 2nd row

CHECK INTERIOR ROOM LAMP CONTROL FUNCTION

CONSULT

  1. Set the front room/map lamp assembly switch and personal lamps 2nd row switch to DOOR:

  2. Ignition switch ON.

  3. Select “INT LAMP” in “Active Test” mode of “BCM(INT LAMP)”.

  4. While operating the test item, check that each interior room lamp turn ON/OFF.

    On : Interior room lamp On
    Off : Interior room lamp Off

Does the interior room lamp turn ON/OFF?

YES>>

Interior room lamp control circuit is normal.

NO>>

Refer to Diagnosis Procedure.

Diagnosis Procedure

CHECK INTERIOR ROOM LAMP CONTROL OUTPUT

CONSULT

  1. Ignition switch ON.

  2. Select “INT LAMP” in “Active Test” mode of “BCM(INT LAMP)”.

  3. While operating the test item, check voltage between BCM harness connector and ground.

BCM — Test item

Voltage

(Approx.)
Connector Terminal
M81 136 Ground INT LAMP On 0 V
Off Battery voltage

Is the inspection result normal?

YES>>

Interior room lamp control circuit is operating normally.

Fixed ON>>

GO TO 3.

Fixed OFF>>

GO TO 2.

CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT

  1. Ignition switch OFF.

  2. Disconnect BCM harness connector and front room/map lamp assembly harness connector.

  3. Check continuity between BCM harness connector and front room/map lamp assembly harness connector.

    BCMFront room/map lamp assemblyContinuity
    ConnectorTerminalConnectorTerminal
    M81 136 R6 6 Yes
  4. Disconnect the personal lamps 2nd row harness connector.

  5. Check continuity between front room/map lamp assembly connector and personal lamps 2nd row harness connector.

    Front room/map lamp assemblyPersonal lamps 2nd rowContinuity
    ConnectorTerminalConnectorTerminal
    R6 7 R16 (LH) 4 Yes
    R17 (RH)

Is the inspection result normal?

YES>>

Check interior room lamps for an open circuit. If there is an open, replace lamp in question. Refer to Removal and Installation for front room/map lamp assembly or Removal and Installation for personal lamps 2nd row. If OK, replace BCM. Refer to Removal and Installation.

NO>>

Repair or replace harness or connectors.

CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT

  1. Ignition switch OFF.

  2. Disconnect BCM harness connector and front room/map lamp harness connector.

  3. Check continuity between BCM harness connector and ground.

    BCM — Continuity
    Connector Terminal
    M81 136 Ground No

Is the inspection result normal?

YES>>

Check interior room lamps for a short circuit. If there is a short, replace lamp in question. Refer to Removal and Installation for front room/map lamp assembly or Removal and Installation for personal lamps 2nd row. If OK, replace BCM. Refer to Removal and Installation.

NO>>

Repair or replace harness or connectors.