Interior Room Lamp Control Circuit
Battery saver output/power supply circuit
Front room/map lamp assembly
Personal lamps 2nd row
CHECK INTERIOR ROOM LAMP CONTROL FUNCTION
CONSULT
Set the front room/map lamp assembly switch and personal lamps 2nd row switch to DOOR:
Ignition switch ON.
Select “INT LAMP” in “Active Test” mode of “BCM(INT LAMP)”.
While operating the test item, check that each interior room lamp turn ON/OFF.
On : Interior room lamp On Off : Interior room lamp Off
Does the interior room lamp turn ON/OFF?
YES>>Interior room lamp control circuit is normal.
NO>>Refer to Diagnosis Procedure.
CHECK INTERIOR ROOM LAMP CONTROL OUTPUT
CONSULT
Ignition switch ON.
Select “INT LAMP” in “Active Test” mode of “BCM(INT LAMP)”.
While operating the test item, check voltage between BCM harness connector and ground.
| BCM | — | Test item | Voltage (Approx.) |
||
| Connector | Terminal | ||||
| M81 | 136 | Ground | INT LAMP | On | 0 V |
| Off | Battery voltage | ||||
Is the inspection result normal?
YES>>Interior room lamp control circuit is operating normally.
Fixed ON>>GO TO 3.
Fixed OFF>>GO TO 2.
CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT
Ignition switch OFF.
Disconnect BCM harness connector and front room/map lamp assembly harness connector.
Check continuity between BCM harness connector and front room/map lamp assembly harness connector.
BCM Front room/map lamp assembly Continuity Connector Terminal Connector Terminal M81 136 R6 6 Yes Disconnect the personal lamps 2nd row harness connector.
Check continuity between front room/map lamp assembly connector and personal lamps 2nd row harness connector.
Front room/map lamp assembly Personal lamps 2nd row Continuity Connector Terminal Connector Terminal R6 7 R16 (LH) 4 Yes R17 (RH)
Is the inspection result normal?
YES>>Check interior room lamps for an open circuit. If there is an open, replace lamp in question. Refer to Removal and Installation for front room/map lamp assembly or Removal and Installation for personal lamps 2nd row. If OK, replace BCM. Refer to Removal and Installation.
NO>>Repair or replace harness or connectors.
CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT
Ignition switch OFF.
Disconnect BCM harness connector and front room/map lamp harness connector.
Check continuity between BCM harness connector and ground.
BCM — Continuity Connector Terminal M81 136 Ground No
Is the inspection result normal?
YES>>Check interior room lamps for a short circuit. If there is a short, replace lamp in question. Refer to Removal and Installation for front room/map lamp assembly or Removal and Installation for personal lamps 2nd row. If OK, replace BCM. Refer to Removal and Installation.
NO>>Repair or replace harness or connectors.