Hazard Switch Circuit
CHECK HAZARD SWITCH SIGNAL
CONSULT
Ignition switch ON.
Select “HAZARD SW” in “Data Monitor” mode of “BCM(FLASHER)”.
While operating the hazard switch, check the monitor status.
Monitor item Condition Monitor status HAZARD SW Hazard switch ON On OFF Off
Is the inspection result normal?
YES>>Hazard switch circuit is normal.
NO>>Refer to Diagnosis Procedure.
CHECK HAZARD SWITCH SIGNAL INPUT
Ignition switch OFF.
Disconnect hazard switch connector.
Check voltage between hazard switch connector and ground.
(+) (−) Voltage
(Approx.)Hazard switch Connector Terminal M83 2 Ground Battery voltage
Is the inspection result normal?
YES>>GO TO 4.
NO>>GO TO 2.
CHECK HAZARD SWITCH SIGNAL (OPEN) CIRCUIT
Disconnect BCM connector.
Check continuity between hazard switch harness connector and BCM harness connector.
Hazard switch BCM Continuity Connector Terminal Connector Terminal M83 2 M18 36 Yes
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness.
CHECK HAZARD SWITCH SIGNAL (SHORT) CIRCUIT
Check continuity between hazard switch harness connector and ground.
| Hazard switch | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| M83 | 2 | Ground | No |
Is the inspection result normal?
YES>>Replace BCM. Refer to Removal and Installation.
NO>>Repair or replace harness.
CHECK HAZARD SWITCH GROUND CIRCUIT
Check continuity between hazard switch harness connector and ground.
| Hazard switch | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| M83 | 3 | Ground | Yes |
Is the inspection result normal?
YES>>Replace hazard switch. Refer to Removal and Installation.