Meter Control Switch Signal Circuit
CHECK METER CONTROL SWITCH SIGNAL
Ignition switch ON.
Check voltage between the following terminals of the meter control switch harness connector.
Meter control switch Condition Voltage
(Approx.)Connector Terminals (+) (−) M27 7 4 When illumination control switch (−) is pressed 0 V Other than the above 5 V 5 When trip reset switch is pressed 0 V Other than the above 5 V 6 When illumination control switch (+) is pressed 0 V Other than the above 5 V
Is the inspection result normal?
YES>>Inspection End.
NO>>GO TO 2.
CHECK METER CONTROL SWITCH CIRCUITS
Ignition switch OFF.
Disconnect combination meter harness connector and meter control switch harness connector.
Check continuity between combination meter harness connector and meter control switch harness connector.
Combination meter Meter control switch Continuity Connector Terminal Connector Terminal M24 18 M27 5 Yes 37 7 36 6 17 4 Check continuity between combination meter harness connector and ground.
Combination meter — Continuity Connector Terminal M24 18 Ground No 37 36 17
Is the inspection result normal?
YES>>Inspection End.
NO>>Repair or replace harness or connector.
CHECK METER CONTROL SWITCH
Ignition switch OFF.
Disconnect meter control switch harness connector.
Check meter control switch.
Meter control switch Condition Continuity Terminals 7 4 When illumination control switch (−) is pressed Yes Other than the above No 5 When trip reset switch is pressed Yes Other than the above No 6 When illumination control switch (+) is pressed Yes Other than the above No
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace meter control switch. Refer to Removal and Installation.