Driver Information & Multimedia

Meter Control Switch Signal Circuit

9steps
~54min
2/5difficulty
Done 0 of 9
Diagnosis Procedure

CHECK METER CONTROL SWITCH SIGNAL

  1. Ignition switch ON.

  2. Check voltage between the following terminals of the meter control switch harness connector.

    Meter control switchCondition

    Voltage

    (Approx.)
    ConnectorTerminals
    (+)(−)
    M27 7 4 When illumination control switch (−) is pressed 0 V
    Other than the above 5 V
    5 When trip reset switch is pressed 0 V
    Other than the above 5 V
    6 When illumination control switch (+) is pressed 0 V
    Other than the above 5 V

Is the inspection result normal?

YES>>

Inspection End.

NO>>

GO TO 2.

CHECK METER CONTROL SWITCH CIRCUITS

  1. Ignition switch OFF.

  2. Disconnect combination meter harness connector and meter control switch harness connector.

  3. Check continuity between combination meter harness connector and meter control switch harness connector.

    Combination meterMeter control switchContinuity
    ConnectorTerminalConnectorTerminal
    M24 18 M27 5 Yes
    37 7
    36 6
    17 4
  4. Check continuity between combination meter harness connector and ground.

    Combination meter—Continuity
    ConnectorTerminal
    M24 18 Ground No
    37
    36
    17

Is the inspection result normal?

YES>>

Inspection End.

NO>>

Repair or replace harness or connector.

Component Inspection

CHECK METER CONTROL SWITCH

  1. Ignition switch OFF.

  2. Disconnect meter control switch harness connector.

  3. Check meter control switch.

    Meter control switchConditionContinuity
    Terminals
    7 4 When illumination control switch (−) is pressed Yes
    Other than the above No
    5 When trip reset switch is pressed Yes
    Other than the above No
    6 When illumination control switch (+) is pressed Yes
    Other than the above No

Is the inspection result normal?

YES>>

Inspection End.

NO>>

Replace meter control switch. Refer to Removal and Installation.