Driver Information & Multimedia

Power Supply and Ground Circuit. Combination Meter

4steps
~24min
2/5difficulty
Done 0 of 4
Diagnosis Procedure

CHECK FUSES

Check that the following fuses are not blown:

UnitPower sourceFuse No.Capacity
Combination meter Battery 7 10 A
13 10 A
Ignition switch ON or ACC 21 10 A
Ignition switch ON or START 31 5 A

Is the fuse blown?

YES>>

Replace the blown fuse after repairing the affected circuit.

NO>>

GO TO 2.

CHECK POWER SUPPLY CIRCUIT

  1. Disconnect combination meter harness connector.

  2. Check voltage between combination meter harness connector and ground.

    (+)(–)Ignition switch position
    Combination meter
    ConnectorTerminalOFFON or ACCSTART
    M24 14 Ground 0 V Battery voltage Battery voltage
    M23 44 0 V Battery voltage Battery voltage
    46 Battery voltage Battery voltage Battery voltage

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace harness or connector.

CHECK GROUND CIRCUIT

  1. Ignition switch OFF.

  2. Check continuity between combination meter harness connector and ground.

    Combination meter—Continuity
    ConnectorTerminal
    M24 10 Ground Yes
    M23 43
    45

Is the inspection result normal?

YES>>

Inspection End.

NO>>

Repair or replace harness or connector.