Driver Information & Multimedia
Power Supply and Ground Circuit. Combination Meter
In this manual: Driver Information & Multimedia
4steps
~24min
2/5difficulty
Done 0 of 4
CHECK FUSES
Check that the following fuses are not blown:
| Unit | Power source | Fuse No. | Capacity |
|---|---|---|---|
| Combination meter | Battery | 7 | 10 A |
| 13 | 10 A | ||
| Ignition switch ON or ACC | 21 | 10 A | |
| Ignition switch ON or START | 31 | 5 A |
Is the fuse blown?
YES>>Replace the blown fuse after repairing the affected circuit.
NO>>GO TO 2.
CHECK POWER SUPPLY CIRCUIT
Disconnect combination meter harness connector.
Check voltage between combination meter harness connector and ground.
(+) (–) Ignition switch position Combination meter Connector Terminal OFF ON or ACC START M24 14 Ground 0 V Battery voltage Battery voltage M23 44 0 V Battery voltage Battery voltage 46 Battery voltage Battery voltage Battery voltage
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness or connector.
CHECK GROUND CIRCUIT
Ignition switch OFF.
Check continuity between combination meter harness connector and ground.
Combination meter — Continuity Connector Terminal M24 10 Ground Yes M23 43 45
Is the inspection result normal?
YES>>Inspection End.
NO>>Repair or replace harness or connector.
Was this page helpful?