REPLACEMENT
Drain the R134a refrigerant circuit using the recharging station.
Remove:
the retaining nut (A) of the connecting pipes,
the two mounting bolts (B) of the expansion valve on the evaporator.

When refitting, make sure the pipe sealing rings are in good condition.
Bolt tightening torques:
bolt (A): 0.8 daN.m,
bolt (B): 0.6 daN.m.
Evacuate the system, then charge the R134a refrigerant circuit using the recharging station.