Heating, air conditioning
Removing and installing air recirculation flap control motor -V113-, LHD vehicles
In this manual: Heating, air conditioning
~2min read
Heater and air conditioning system with electric/manual controlsSpecial tools and workshop equipment requiredVehicle diagnostic tester Note The control motor has end stops with integrated limit switches instead of a potentiometer. First carry out the following work:
Removing
|
Installing |
![]() |
Installation is carried out in the reverse order. When installing, note the following: Note
Check operation of flaps and hinge mechanism before fitting.Make sure levers and shafts are properly fitted in the mounts.
The operating shaft -2- must be on the stop -1--arrow- as shown. Note If the control motor operating shaft is not on the “fresh air mode” stop, rotate the receptacle in the control motor.
Note If the bolts cannot be fitted, the control motor is not completely seated on the housing.
Specified torque→ Chapter „Assembly overview - heater and air conditioning unit“Compartments/covers; Assembly overview - glove compartment → General body repairs, interior; Rep. gr.68. |
![]() |
Test yourself
A quick Volkswagen Golf quiz: every answer comes with an explanation and a link to the manual page.
Was this page helpful?
Note The control motor has end stops with integrated limit switches instead of a potentiometer. 