  1. Refer to: Health and Safety Precautions (100-00 General Information, Description and Operation).
  2. NOTICE: Do not overrotate the clockspring inner rotor. The inner ribbon cable is connected to the clockspring rotor. The inner ribbon cable acts as a stop and can be torn from the inside connection. Failure to follow this instruction may result in damage to the component and/or system malfunction.

    1. Turn counterclockwise until resistance is felt, then turn clockwise so the electrical connector is in the 12 o'clock position.
    1. Turn the component clockwise 3 full turns.