Ignition System

Ignition Coil Inspection

~1min read

PROCEDURE

1. Измерьте сопротивление между контактами 1 и 2 разъема C11-2 (катушки цилиндров

1. Measure the resistance between terminals 1 and 2 of connector C11-2 (cylinders 1 and 4 coils) and between terminals 1 and 2 of connector C11-1 (cylinders 2 and 3 coils).

Resistance: 0.5±0.05 kΩ

2. Измерьте сопротивление вторичной обмотки между катушки зажигания клеммами

2. Measure the secondary winding resistance between the high-tension terminals of the ignition coil for cylinders 1 and 4, and between the terminals for cylinders 2 and 3.
Resistance: 12.1±1.8 kΩ

Предупреждение

When measuring the secondary winding resistance of the ignition coil, make sure to disconnect the electrical connector of the ignition coil.

Test yourself