PCV Valve
Removal
PROCEDURE
1. Disconnect the hose from the PCV valve. Remove the valve from the cylinder head cover and connect it to the PCV hose.
2. Start the engine at idle speed, cover the valve opening with your finger and check that vacuum created in the intake manifold can be felt.

The PCV valve plunger does not move back and forth.

3. If no vacuum is felt, clean the PCV valve and hose or replace them.
Inspection
PROCEDURE
1. Remove the PCV valve.
2. To check plunger movement, insert a thin steel rod from the threaded end of the valve.
3. If the plunger does not move, the valve is clogged and must be cleaned or replaced.
Installation
PROCEDURE
Install the PCV valve and tighten it to the specified torque.
Tightening torque: 8–12 N•m
Test yourself