Replacement
- If the compressor is locked up, run the engine at idle and let the air conditioner operate for a few minutes, then stop the engine.
- Disconnect the negative (-) battery terminal.
- Recover the refrigerant using a recovery/recharging station.
- Remove the engine cover (A).

- Remove the bolts and the expansion valve (A) from the evaporator core.
Tightening torque: 8.8 ~ 13.7 N·m

- Remove the 2 nuts, then disconnect the discharge line (A) and liquid line (B) from the condenser.
Tightening torque: 8.8 ~ 13.7 N·m

- Disconnect the air conditioner pressure sensor connector (A).

- Remove the engine room cover. (Refer to Engine Mechanical System - "Engine Room Cover")
- Remove the bolts, then disconnect the suction line (A) and discharge line (B) from the compressor.
Tightening torque: 21.6 ~ 32 N·m

- Plug or cover the lines immediately after disconnecting them to prevent moisture and dust from entering.
- Loosen the mounting bolt of the bracket (B) on the suction and liquid line assembly (A).
Tightening torque: 7.8 ~ 11.8 N·m
- Remove the refrigerant line assembly (A) toward the upper part of the engine room.

- To install, reverse the removal procedure.

- Plug or cover the lines immediately after disconnecting them to prevent moisture and dust from entering.
- Tighten the bolt or nut to the specified torque.
- Check for refrigerant leaks using a gas leak detector.
- Evacuate the air conditioning system and charge it with refrigerant.
Capacity of the compressor: 500 ± 25 g (17.6 ± 0.88 oz)