Heating, Ventilation, and Air Conditioning
Ambient Temperature Sensor Repair Procedures
In this manual: Heating, Ventilation, and Air Conditioning
7steps
~42min
2/5difficulty
Done 0 of 7
Inspection
- Check the resistance of the ambient temperature sensor between terminals 1 and 2 and verify that it changes as the ambient temperature changes.

1. Ambient Temperature Sensor (+) 2. Sensor Ground
SpecificationAmbient Temperature
[°C (°F)]Resistance between terminals 1 and 2 (kΩ) -10 (14) 164,2 0 (32) 97,5 10 (50) 59,6 20 (68) 37,46
Diagnosis Using GDS
- The heating, ventilation, and air conditioning system faults can be quickly diagnosed using the Global Diagnostic System (GDS). ※ The GDS provides the following information: (1) Self-diagnosis: Check and display of diagnostic trouble codes (DTC). (2) Current data: Check the input/output status of system data. (3) Active test: Check the operating status of the system. (4) Additional functions: Other controls such as system option and zero point adjustment.
- Select "Vehicle Model" and the system to be checked to inspect the vehicle with the tester.
- Select the "Current Data" menu to check the current input/output data status. The input/output data for the sensors related to the ambient temperature sensor can be checked.

Replacement
- Disconnect the negative (-) battery terminal.
- Remove the front bumper. (Refer to Body - "Front Bumper Cover")
- Disconnect the connector (A) and remove the ambient temperature sensor (B).

- To install, reverse the removal procedure.