Electric Vehicle Battery System
High Voltage Disconnection Procedure
In this manual: Electric Vehicle Battery System
6steps
~36min
2/5difficulty
Done 0 of 6
High Voltage Disconnection Procedure
|
- Turn the ignition OFF and disconnect the negative (-) terminal of the auxiliary battery.
- Remove the cover (A) from the rear seat floor mat.
- Loosen the nut and remove the service cover of the safety plug (A). Service cover mounting nut: 7.8 ~ 11.8 N·m
- Remove the safety plug (A).
- Wait at least 5 minutes or until the capacitor in the high-voltage system is fully discharged.
- Measure the voltage between the inverter terminals to confirm that the capacitor in the inverter is fully discharged.
- Raise the vehicle.
- Remove the high-voltage battery lower cover (A) by loosening the bolt.
- Disconnect the high-voltage cable (A).
- Measure the voltage between the inverter terminals. Less than 30 V: High-voltage circuit is properly closed. More than 30 V: Malfunction in the high-voltage circuit.
If the measured voltage exceeds 30 V even though the service plug has been removed properly, there may be a serious problem in the high voltage circuit. In this case, check the DTCs and never touch the high voltage system.
Test yourself
A quick Kia Soul EV Owner's Manual quiz: every answer comes with an explanation and a link to the manual page.
Was this page helpful?