Tightening torques

connecting flange mounting bolt 0.8 daN.m
pipe connection fixing bolts 0.8 daN.m
battery cover bolts 0.4 daN.m

REMOVAL

  • Disconnect the battery, starting with the negative terminal.
  • Remove the engine covers.
  • Drain the refrigerant circuit using a recovery/recharge station.

F9Q or K4M or K9K

Bride de liaison
  • Unclip the sound insulation from the bulkhead.
  • Unscrew the pipe connections (1) from the connecting flange.
  • Disconnect the pipes.
  • Fit plugs to the openings.

K4J

Bride de liaison
  • Remove the air box (2) (Chapter Fuel Mixture).
  • Release the fuel cut-off solenoid valve (3).
Bride de liaison
  • Unclip the sound insulation from the bulkhead.
  • Unscrew the pipe connections (4) from the connecting flange.
  • Disconnect the pipes.
  • Fit plugs to the openings.

F4R

Bride de liaison
  • Remove:
  • the wiper arms,
  • the left and right pillars.
Bride de liaison
  • Remove:
  • the bulkhead seal (5),
  • the plastic rivets (6),
  • the cowl grille (7).
Bride de liaison
  • Remove:
  • the mounting clips (8) of the water box cover,
  • the water box cover (9),
  • the heat shield mountings.
Bride de liaison
  • Unscrew the pipe connections (10) from the connecting flange.
  • Disconnect the pipes.
  • Fit plugs to the openings.
Bride de liaison
  • Remove the two connecting flange mounting bolts (11).
  • Refit a pipe connection bolt in order to extract the connecting flange.
  • Remove the O-rings from the evaporator pipes.

INSTALLATION

Bride de liaison
  • Refit the O-rings onto the pipes (12).
  • Refit in the reverse order of removal.
  • Gradually tighten the two connecting flange mounting bolts so that the connecting flange is evenly pressed onto the pipes.
  • Check that the seal seating surfaces on the connecting flange and the sealing gaskets are in good condition.
  • Replace the seals.
  • Lubricate with the recommended air conditioning oil to ease fitting.

Note: Any damaged seal requires replacement of the pipe.

  • Tighten to the following torques:
  • the connecting flange mounting bolt (0.8 daN.m),
  • the pipe connection mounting bolts (0.8 daN.m),
  • the battery cover bolts (0.4 daN.m).
WARNING

Connect the battery; carry out the necessary relearn procedures (Chapter Battery).

  • Refill the refrigerant circuit using a recovery/recharge station.
Note:
  • Check the air conditioning operates correctly with the fan unit at maximum speed.
  • If there is no cooling, carry out a leak check (see Air Conditioning chapter).
Note: When replacing a connecting flange, add 10 ml of the recommended oil to the quantity recovered.