Air conditioning
Connecting flange
In this manual: Air conditioning
~2min read
B84 ou C84 ou S84
Essential equipment |
| charging station |
Tightening torques |
|
| connecting flange mounting bolt | 0.8 daN.m |
| pipe connection fixing bolts | 0.8 daN.m |
| battery cover bolts | 0.4 daN.m |
REMOVAL
- Disconnect the battery, starting with the negative terminal.
- Remove the engine covers.
- Drain the refrigerant circuit using a recovery/recharge station.
F9Q or K4M or K9K

- Unclip the sound insulation from the bulkhead.
- Unscrew the pipe connections (1) from the connecting flange.
- Disconnect the pipes.
- Fit plugs to the openings.
K4J

- Remove the air box (2) (Chapter Fuel Mixture).
- Release the fuel cut-off solenoid valve (3).

- Unclip the sound insulation from the bulkhead.
- Unscrew the pipe connections (4) from the connecting flange.
- Disconnect the pipes.
- Fit plugs to the openings.
F4R

- Remove:
- the wiper arms,
- the left and right pillars.

- Remove:
- the bulkhead seal (5),
- the plastic rivets (6),
- the cowl grille (7).

- Remove:
- the mounting clips (8) of the water box cover,
- the water box cover (9),
- the heat shield mountings.

- Unscrew the pipe connections (10) from the connecting flange.
- Disconnect the pipes.
- Fit plugs to the openings.

- Remove the two connecting flange mounting bolts (11).
- Refit a pipe connection bolt in order to extract the connecting flange.
- Remove the O-rings from the evaporator pipes.
INSTALLATION

- Refit the O-rings onto the pipes (12).
- Refit in the reverse order of removal.
- Gradually tighten the two connecting flange mounting bolts so that the connecting flange is evenly pressed onto the pipes.
- Check that the seal seating surfaces on the connecting flange and the sealing gaskets are in good condition.
- Replace the seals.
- Lubricate with the recommended air conditioning oil to ease fitting.
Note: Any damaged seal requires replacement of the pipe.
- Tighten to the following torques:
- the connecting flange mounting bolt (0.8 daN.m),
- the pipe connection mounting bolts (0.8 daN.m),
- the battery cover bolts (0.4 daN.m).
Connect the battery; carry out the necessary relearn procedures (Chapter Battery).
- Refill the refrigerant circuit using a recovery/recharge station.
- Check the air conditioning operates correctly with the fan unit at maximum speed.
- If there is no cooling, carry out a leak check (see Air Conditioning chapter).