Entire Combination Meter does not Operate
This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch is turned to ON, the indicators will not operate.
WIRING DIAGRAM
PROCEDURE
CHECK HARNESS AND CONNECTOR
(a) Disconnect the F14 meter connector. |
![]() |
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
F14-20 (E1) - Body ground |
Always |
Below 1 Ω |
F14-13 (MGND) - Body ground |
Always |
Below 1 Ω |
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
F14-17 (IG+) - Body ground |
Ignition switch ON |
11 to 14 V |
F14-15 (B) - Body ground |
Always |
11 to 14 V |
*a |
Front view of wire harness connector (to Combination Meter Assembly) |
| OK | ![]() | REPLACE COMBINATION METER ASSEMBLY |
| NG | ![]() | REPAIR OR REPLACE HARNESS OR CONNECTOR |