Vehicle Interior
Inspection
INSPECTION PROCEDURE
1. INSPECT NO. 1 COOLER THERMISTOR
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
1 - 2 |
-10°C (14°F) |
7.30 to 9.10 kΩ |
1 - 2 |
-5°C (23°F) |
5.65 to 6.95 kΩ |
1 - 2 |
0 °C |
4.40 to 5.35 kΩ |
1 - 2 |
5 °C |
3.40 to 4.15 kΩ |
1 - 2 |
10 °C |
2.70 to 3.25 kΩ |
1 - 2 |
15 °C |
2.14 to 2.58 kΩ |
1 - 2 |
20 °C |
1.71 to 2.05 kΩ |
1 - 2 |
25 °C |
1.38 to 1.64 kΩ |
1 - 2 |
30 °C |
1.11 to 1.32 kΩ |
HINT:
As the temperature increases, the resistance decreases (refer to the graph).
NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring the resistance, make sure the sensor temperature is almost the same as the ambient temperature.
If the result is not as specified, replace the No. 1 cooler thermistor. Text in Illustration
*1 |
Sensor |
*a |
Component without harness connected
(No. 1 Cooler Thermistor) |
*b |
Resistance (kΩ) |
*c |
Temperature (°C(°F)) |
|
 |
?