Heater / Air Conditioning

Disassembly

~1min read

DISASSEMBLY

PROCEDURE

1. PRECAUTIONS

NOTICE:

Be sure to perform initialization after replacing the blower damper servo sub-assembly No. 1. If initialization is not performed, the air conditioning unit assembly will not operate properly, because the air conditioning amplifier assembly will not be able to recognize the position of the blower damper servo sub-assembly No. 1.

2. REMOVE AIR FILTER COVER PLATE

(a) Release the claw and guides as shown in the illustration to remove the air filter cover plate.

Remove in this direction (1)

Remove in this direction (2)

3. REMOVE AIR PURIFICATION FILTER

(a) Remove the air filter sub-assembly as shown in the illustration.

Remove in this direction

(b) Release the guides to remove the air purification filter from the cooling unit parts.

4. REMOVE BLOWER MOTOR SUB-ASSEMBLY WITH FAN

(a) Remove the 3 screws and the blower motor sub-assembly with fan.

5. REMOVE BLOWER DAMPER SERVO ASSY NO. 1

(a) Remove the 2 screws and the Blower Damper Servo Assy No. 1.