Heater / Air Conditioning

Reassembly

~2min read

REASSEMBLY

PROCEDURE

1. INSTALL BLOWER DAMPER SERVO ASSY NO. 1

(a) Connect the 2 link rods of the blower assembly to the 2 plates of the Blower Damper Servo Assy No. 1 as shown in the illustration.

*a

Link

(b) Install the Blower Damper Servo Assy No. 1 using the 2 screws.

2. INSTALL BLOWER MOTOR AND FAN ASSEMBLY

(a) Install the blower motor and fan assembly using the 3 screws.

NOTICE:

Replace the blower motor and fan assembly if it has been dropped or subjected to a severe impact.

3. INSTALL AIR PURIFICATION FILTER

(a) Engage the guides on the cutout of the cooling unit components, then engage the guides as shown in the illustration to install the air purification filter.

*a

Cutout

*b

Rib

Install in this direction (1)

Install in this direction (2)

NOTICE:

  • Make sure that the "UP" marks are facing the correct direction before installing the air purification filter.
  • Make sure that there is no gap between the air purification filter and the cooling unit components, and that the air purification filter is not deformed.

(b) Install the air filter sub-assembly as shown in the illustration.

Install in this direction

NOTICE:

Make sure that the "UP" mark is facing the correct direction before installing the air filter sub-assembly.

4. INSTALL AIR FILTER COVER PLATE

(a) Engage the guides and claw as shown in the illustration to install the air filter cover plate.

Install in this direction (1)

Install in this direction (2)