Removal
REMOVAL
PRECAUTION / NOTICE / HINT
The procedures required (adjustment, calibration, initialization or registration) that must be performed after parts have been removed, installed or replaced during blower unit removal/installation are shown below.
Procedure Required After Replacing / Removing / Installing PartsReplacement part or procedure | Necessary Procedures | Effects / Inoperative Function When Necessary Procedure Not Performed | Link |
|---|---|---|---|
Disconnect the cable from the negative (-) battery terminal. |
Memorize Steering Angle Neutral Point |
Lane Departure Alert System (with Steering Control) |
|
Pre-Collision System |
|||
Initialize Back Door Lock |
Door Lock Control System |
||
No. 1 Blower Door Servo Sub-assembly |
Initialize Servo Motor (Air Conditioning System) |
DTCs are stored |
PROCEDURE
1. PRECAUTIONS
NOTICE:
Be sure to perform initialization after replacing the blower damper servo sub-assembly No. 1. If initialization is not performed, the air conditioning unit assembly will not operate properly, because the air conditioning amplifier assembly will not be able to recognize the position of the blower damper servo sub-assembly No. 1.
2. REMOVE AIR CONDITIONING UNIT ASSEMBLY
Click here![]()
3. REMOVE AIR DUCT NO. 2
Click here![]()
4. REMOVE INSTRUMENT PANEL WIRE NO. 3 (with PTC Heater)
Click here![]()
5. REMOVE BLOWER ASSEMBLY
(a) Disconnect the connector. |
![]() |
(b) Release the guide.
(c) Remove the 2 screws. |
![]() |
(d) Release the guides to remove the blower assembly from the cooler condenser assembly.
.gif)