Removal
REMOVAL
PROCEDURE
1. RECOVER REFRIGERANT FROM REFRIGERANT SYSTEM
- for HFC-134a (R134a):
Click here
.gif)
- for HFO-1234yf (R1234yf):
Click here
.gif)
2. REMOVE PIPE CLAMP (for DENSO Manufacturer)
(a) for suction hose assembly:
(1) While pushing the end of the suction hose assembly into the end of the suction pipe assembly, use pliers to compress both sides of the pipe clamp together until it breaks.
*1 |
Suction Pipe Sub-assembly |
*2 |
Suction Hose Sub-assembly. |
*3 |
Pipe Clamp |
- |
- |
*a |
Push in |
- |
- |
NOTICE:
- If foreign objects are stuck to the connector, use a brush or compressed air to remove them.
- Make sure that fragments of the pipe clamp do not enter the pipe.
(2) Disconnect the suction hose sub-assembly.
NOTICE:
Remove any foreign matter near the ends of the suction hose sub-assembly and the suction pipe sub-assembly.
(3) Remove the 2 O-rings from the suction hose sub-assembly.
NOTICE:
Wrap the free ends of the disconnected suction pipe sub-assembly and suction hose sub-assembly with vinyl tape to prevent moisture and foreign matter from entering.
(4) Remove the pipe clamp.
(b) for Refrigerant Cooler Liquid Tube A:
Click here![]()