Installation
INSTALLATION
PROCEDURE
1. INSTALL PIPE CLAMP (DENSO make)
(a) for suction hose assembly:
(1) Remove the vinyl tape from the free ends of the suction pipe sub-assembly and the suction hose sub-assembly.
(2) Install a new pipe clamp onto the suction hose sub-assembly. NOTICE:
|
|
(3) Thoroughly apply compressor oil to 2 new O-rings and to the contact surface of the suction hose sub-assembly.
Compressor oil:
ND-OIL 12 or equivalent
(4) Install the 2 O-rings onto the suction hose sub-assembly.
NOTICE:
Prevent foreign matter from adhering to the O-rings or the O-ring sealing surfaces.
(5) Connect the suction pipe sub-assembly and the suction hose sub-assembly, aligning the alignment marks. NOTICE: Insert the parts while holding the pipe, not the pipe clamp. |
|
(6) Insert the pipe clamp correctly until the large-diameter section of the pipe clamp is covered by the suction pipe sub-assembly. HINT:
|
|
(b) for Refrigerant Cooler Liquid Tube A:
Click here![]()
2. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
- for HFC-134a (R134a):
Click here
.gif)
- for HFO-1234yf (R1234yf):
Click here
.gif)
3. WARM UP ENGINE
- for HFC-134a (R134a):
Click here
.gif)
- for HFO-1234yf (R1234yf):
Click here
.gif)
4. CHECK FOR REFRIGERANT LEAKS
- for HFC-134a (R134a):
Click here
.gif)
- for HFO-1234yf (R1234yf):
Click here
.gif)