INSTALLATION

PROCEDURE

1. INSTALL PIPE CLAMP (DENSO make)

(a) for suction hose assembly:

(1) Remove the vinyl tape from the free ends of the suction pipe sub-assembly and the suction hose sub-assembly.

(2) Install a new pipe clamp onto the suction hose sub-assembly.

NOTICE:

  • Firmly engage the inner projection of the pipe clamp in the groove of the suction hose sub-assembly.
  • When installing, do not widen the opening of the pipe clamp beyond the diameter of the suction hose sub-assembly.
  • Do not install the pipe clamp with the large-diameter section facing the wrong direction.

*1

Suction Hose Sub-assembly.

*2

Pipe Clamp

*a

Groove

(3) Thoroughly apply compressor oil to 2 new O-rings and to the contact surface of the suction hose sub-assembly.

Compressor oil:

ND-OIL 12 or equivalent

(4) Install the 2 O-rings onto the suction hose sub-assembly.

NOTICE:

Prevent foreign matter from adhering to the O-rings or the O-ring sealing surfaces.

(5) Connect the suction pipe sub-assembly and the suction hose sub-assembly, aligning the alignment marks.

NOTICE:

Insert the parts while holding the pipe, not the pipe clamp.

*a

Large-diameter section of pipe clamp

*b

Alignment Mark

(6) Insert the pipe clamp correctly until the large-diameter section of the pipe clamp is covered by the suction pipe sub-assembly.

HINT:

  • When inserting, make sure a click is heard.
  • Make sure the suction hose sub-assembly is correctly inserted by pulling on it.

*a

Large-diameter section of pipe clamp

(b) for Refrigerant Cooler Liquid Tube A:

Click here

2. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT

  • for HFC-134a (R134a):

    Click here

  • for HFO-1234yf (R1234yf):

    Click here

3. WARM UP ENGINE

  • for HFC-134a (R134a):

    Click here

  • for HFO-1234yf (R1234yf):

    Click here

4. CHECK FOR REFRIGERANT LEAKS

  • for HFC-134a (R134a):

    Click here

  • for HFO-1234yf (R1234yf):

    Click here