Heater / Air Conditioning

Installation

~4min read
010203040509.87N·mlb·ft
Tightening torque found on this page

INSTALLATION

PROCEDURE

1. REFILL COMPRESSOR OIL

(a) When replacing the compressor with pulley assembly with a new part, gradually discharge the refrigerant gas through the service valve. Then drain the following amount of oil from the new compressor with pulley assembly before installation, so that its oil volume is the same as that of the compressor with pulley assembly being replaced.

Standard:

(Oil quantity inside new cooler compressor with pulley assembly: 70 (+15) cm3 (2.37 (+0.507) fl. oz.)) - (Oil quantity remaining in removed compressor with pulley assembly A) = (Oil quantity to drain when replacing cooler compressor with pulley assembly)

HINT:

A new cooler compressor with pulley assembly is filled with enough oil for the entire system. For this reason, it is necessary to drain the residual oil from the condenser and cooler unit. Example: If A is 45 cm3 (1.52 fl. oz.), then 70 cm3 (2.37 fl. oz.) - 45 cm3 (1.52 fl. oz.) = 25 cm3 (0.845 fl. oz.), so drain 25 cm3 (0.845 fl. oz.) of oil from the new cooler compressor with pulley assembly.

NOTICE:

  • When A exceeds the standard oil fill volume specified for the compressor with pulley assembly by part number, install the compressor with pulley assembly without adjusting the oil volume. Example: If A is 70 cm3 (2.37 fl. oz.), A is greater than 70 cm3 (2.37 fl. oz.) and less than 85 cm3 (2.87 fl. oz.), therefore install the cooler compressor with pulley assembly as is.
  • When checking the compressor oil level, observe the recommended precautions for removing and installing the cooler.
  • If a new cooler compressor with pulley assembly is installed without draining the same amount of oil as remains in the vehicle's pipes, the oil quantity will be excessive. This prevents any heat exchange in the refrigerant cycle and may cause a refrigeration malfunction.
  • If the amount of oil remaining in the removed compressor with pulley assembly is insufficient, check for a possible oil leak.
  • Use ND-OIL 12 compressor oil or equivalent.

2. INSTALL COMPRESSOR WITH PULLEY ASSEMBLY

(a) Using a TORX E8 socket wrench, temporarily install the compressor with pulley assembly using the 2 stud bolts.

Torque:

9.8 N·m {100 kgf·cm, 87 in·lbf}

(b) Temporarily install the 2 bolts and 2 nuts.

(c) Tighten the 2 bolts and 2 nuts to install the compressor with pulley assembly in the direction shown in the illustration.

Torque:

25 N·m {255 kgf·cm, 18 ft·lbf}

3. CONNECT SUCTION HOSE SUB-ASSEMBLY

(a) Remove the vinyl tape from the suction hose sub-assembly.

(b) Apply a sufficient amount of compressor oil to a new O-ring and to the connecting surface of the compressor with pulley assembly.

Compressor oil:

ND-OIL12 or equivalent

(c) Install the O-ring to the suction hose sub-assembly.

NOTICE:

Keep the O-ring and O-ring connection surface free of foreign matter.

(d) Connect the suction hose sub-assembly to the compressor with pulley assembly with the bolt.

Torque:

9.8 N·m {100 kgf·cm, 87 in·lbf}

4. CONNECT DISCHARGE HOSE SUB-ASSEMBLY

(a) Remove the vinyl tape from the discharge hose sub-assembly.

(b) Apply a sufficient amount of compressor oil to a new O-ring and to the connecting surfaces of the cooler compressor with pulley assembly.

Compressor oil:

ND-OIL 12 or equivalent

(c) Install the O-ring to the discharge hose sub-assembly.

NOTICE:

Keep the O-ring and O-ring connection surface free of foreign matter.

(d) Connect the suction hose sub-assembly to the compressor with pulley assembly with the bolt.

Torque:

9.8 N·m {100 kgf·cm, 87 in·lbf}

(e) Connect the connector.

5. INSTALL FAN AND GENERATOR V BELT

Click here

6. INSTALL ENGINE UNDER COVER SUB-ASSEMBLY NO. 1

Click here

7. CHARGE REFRIGERANT INTO AIR CONDITIONING SYSTEM (for HFO-1234yf (R1234yf))

Click here

8. WARM UP ENGINE (for HFO-1234yf (R1234yf))

Click here

9. CHECK FOR REFRIGERANT LEAKS (for HFO-1234yf (R1234yf))

Click here