Inspection
INSPECTION
PROCEDURE
1. INSPECT VACUUM PUMP VANE
(a) Check that the vacuum pump vane or vacuum pump vane plugs are not damaged or excessively worn. HINT: If the vacuum pump vane or vacuum pump vane plugs are damaged or excessively worn, replace the damaged parts with new ones. |
|
(b) Using a micrometer, measure the length (A) of the vacuum pump vane with the vacuum pump vane plugs removed. Minimum length (A): 23.8 mm (0.937 in.) NOTICE: Measure length (A) 10 mm (0.394 in.) from each end of the vacuum pump vane. HINT: If the length is not as specified, replace the vacuum pump vane and vacuum pump vane plugs with new ones. |
|
(c) Using a vernier caliper, measure the length (B) of the vacuum pump vane with the vacuum pump vane plugs installed. Minimum length (B): 76 mm (2.99 in.) NOTICE: Measure length (B) 5 mm (0.197 in.) from each end of the vacuum pump vane plug. HINT: If the length is not as specified, replace the vacuum pump vane and vacuum pump vane plugs with new ones. |
|
2. INSPECT VACUUM PUMP HOUSING
(a) Check that the rotor part, connection, vacuum pump housing and end cover are not excessively damaged or worn. HINT: If the rotor part, connection, vacuum pump housing or end cover is excessively damaged or worn, replace the vacuum pump assembly. |
![]() |