Heater / Air Conditioning

Inspection

~1min read

INSPECTION

PROCEDURE

1. INSPECT NO. 1 COOLER THERMISTOR

(a) Check the resistance.

(1) Measure the resistance according to the value(s) shown in the table below.

*a

Component without wire harness connected

(No. 1 Cooler Thermistor)

*b

Sensing Part

*c

Resistance (kΩ)

*d

Temperature (°C (°F))

*e

Allowable Range

-

-

Standard resistance:

Tester Connection

Condition

Specified Condition

1 - 2

-10°C (14°F)

16.86 to 16.36 kΩ

-5°C (23°F)

12.86 to 12.54 kΩ

0 °C

9.89 to 9.70 kΩ

5 °C

7.70 to 7.52 kΩ

10 °C

6.04 to 5.89 kΩ

15 °C

4.77 to 4.65 kΩ

20 °C

3.81 to 3.69 kΩ

25 °C

3.05 to 2.95 kΩ

30 °C

2.46 to 2.37 kΩ

If the resistance is not as specified, replace the No. 1 cooler thermistor.

NOTICE:

  • Hold the sensor by its connector only. Touching the detection area may change the resistance value.
  • When measuring, the temperature sensor must indicate the ambient temperature.

HINT:

Resistance decreases as temperature increases (see graph).

If the specified condition is not met, replace the No. 1 cooler thermistor.