Vehicle Interior
Voltage Meter Malfunction
DESCRIPTION
The voltmeter indicates the voltage applied to the IG+ terminal of the combination meter assembly.
WIRING DIAGRAM
NOTICE:
Inspect the fuses for circuits related to this system before performing procedure.
PROCEDURE
PERFORM ACTIVE TEST USING TECHSTREAM (VOLTMETER)
(a) Operate the Techstream according to the display and select "Active Test" (See page ). Combination Meter:
Tester Display | Test Part | Control Range | Diagnostic Note |
Volt Meter Operation |
Voltmeter |
OFF, 0 V, 3 V, 6V , 9 V, 12 V, 15 V or 18 V |
Perform the test with the vehicle stopped and engine idling |
OK:
Needle indication is normal.
| NG |
 |
REPLACE COMBINATION METER ASSEMBLY |
| OK |
 |
|
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
*a |
Rear view of wire harness connector
(to Combination Meter Assembly) |
(a) Disconnect the J28 combination meter assembly connector.
(b) Measure the resistance and voltage according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
J28-24 (ES) - Body ground |
Always |
Below 1 Ω |
Standard Voltage:
Tester Connection | Switch Condition | Specified Condition |
J28-2 (IG+) - Body ground |
Ignition switch ON |
11 to 14 V |
Ignition switch off |
Below 1 V |
| OK |
 |
REPLACE COMBINATION METER ASSEMBLY |
| NG |
 |
REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
Was this page helpful?