Test equipment and tools
Overview of test equipment, tools and materials
![]()
Note
This overview lists the test equipment, tools and materials required for proper repair of the refrigerant circuit.
![]()
Caution!
Tools or materials that are not approved (e.g. leak-stop additives) can cause damage or impairment to the system.
Only tools and materials approved by the manufacturer may be used.
If tools or materials that are not approved have been used, there is no warranty.
Tools and materials available from the distribution center or importer




Tools and materials available from specialist retailers
![]()
Caution!
Tools or materials that are not approved (e.g. leak-stop additives) can cause damage or impairment to the system.
Only tools and materials approved by the manufacturer may be used.
If tools or materials that are not approved have been used, there is no warranty.

Tools you make yourself

Tools and materials available from the distribution center or importer
![]()
Caution!
Tools or materials that are not approved (e.g. leak-stop additives) can cause damage or impairment to the system.
Only tools and materials approved by the manufacturer may be used.
If tools or materials that are not approved have been used, there is no warranty.
Air conditioning service station -VAS 6007A- (and other or currently available air conditioning service stations)
- Carry out the work steps Test, Recovery (recycling), Evacuate and Charge in accordance with the associated operating instructions.
- The installed filters and dryers must be replaced at the latest after the service life stated in the operating instructions and after each emptying of the station (keep replacement filters on hand). Available from the equipment manufacturer, see operating instructions.
- Air conditioning service stations or flushing devices not shown here, which have been approved by VW, may also be used.
![]()
Note
- This air conditioning service station combines the following known individual units: charging cylinder, manifold gauge set, vacuum pump, shut-off valves and charging hoses.
- Each air conditioning service station includes one quick coupling (for high- and low-pressure side service connections).

Flushing device for refrigerant circuits -VAS 6337/1- from "Behr" or successor model
![]()
Note
- With filter -1- and two large cylindrical sight glasses
- Depending on the type and severity of contamination of the refrigerant circuit being flushed, replace the filter in the flushing device for refrigerant circuits after 2 flushing cycles at the latest. If a heavily contaminated refrigerant circuit is flushed (the refrigerant oil from the refrigerant circuit is black and viscous or there are many metal shavings in the refrigerant circuit), replace the filter after flushing the refrigerant circuit.

Flushing device for refrigerant circuits -VAS 6336/1- from "Waeco" or successor model
![]()
Note
- With filter -1- and one sight glass
- Depending on the type and severity of contamination of the refrigerant circuit being flushed, replace the filter in the flushing device for refrigerant circuits after 2 flushing cycles at the latest. If a heavily contaminated refrigerant circuit is flushed (the refrigerant oil from the refrigerant circuit is black and viscous or there are many metal shavings in the refrigerant circuit), replace the filter after flushing the refrigerant circuit.

Leak detector -V.A.G 1796-

Leak detection system -VAS 6196-

Leak detection system VAS 6201 or successor model

Release tool case -VAS 6127- consisting of release tool sets -VAS 6127/1-, release tool -VAS 6127/2- and release tool -VAS 6127/3-

Release tool -VAS 6127/1-, release tool -VAS 6127/2-
- blue 1/2 inch
- black 5/8 inch
- red 3/8 inch
- white 3/4 inch

Release tool -VAS 6127/3-
- green NW 8 for the high-pressure line
- black NW 13 for the low-pressure line

Counterholder -V.A.G 1616- for clutch plate (for Sanden compressor)

Puller -V.A.G 1616/1- (for Sanden compressor)

Puller for magnetic clutch -V.A.G 1719- (for Zexel compressor)

Adapter set for refrigerant circuit -V.A.G 1785/1-10-
- Adapter for cleaning the refrigerant circuit (flush with refrigerant R134a) or for blowing through with compressed air and nitrogen
- Thread 5/8"-18 UNF for cone-seat seal
- Union nut (for O-ring connection) with thread
- M 18x1,5 V.A.G 1785/1
- M 20x1,5 V.A.G 1785/2
- M 24x1,5 V.A.G 1785/3
- M 28x1,5 V.A.G 1785/4
- Thread 5/8"-18 UNF for cone-seat seal
- Threaded nipple for O-ring
- M 18x1,5 V.A.G 1785/5
- M 20x1,5 V.A.G 1785/6
- M 24x1,5 V.A.G 1785/7

- M 28x1,5 V.A.G 1785/8

Valve adapter
- Thread 5/8"-18 UNF for cone-seat seal
- Internal thread with valve core remover M 10x1.25 V.A.G 1785/9 (for connections with valve on the high-pressure side) M 12x1.5 V.A.G 1785/10 (for connections on the low-pressure side)
![]()
Note
- A Schrader valve is screwed into connection -A-.
- A valve core remover must be installed in the connection of the charging hoses.

Insert socket -T10364- for valves of the high/low-pressure side service connections in the refrigerant circuit

Tools and materials available from specialist retailers
Fin comb

Charging hoses
Thread 5/8"-18 UNF
![]()
Note
- Use charging hoses of different colors, 1800 mm long.
- Keep valve core removers and replacement seals on hand.

Cylinder connection piece for refrigerant cylinder with sealing ring, quick-release connection or threaded connection 5/8''-18 UNF

Valve caps with replacement seals (for thread 5/8''-18 UNF)
Seals can also be used for charging hoses.

Manifold gauge set with pressure regulator for nitrogen (maximum reducing pressure: 15 bar)
- Manifold gauge set with pressure regulator
- Pressure hose (inside diameter 5 mm, length 2 m) with hose fittings
- Nitrogen cylinder
- Hose fitting
![]()
Note
Hose fittings for connecting to the adapter set for refrigerant circuit -V.A.G 1785- with thread 5/8"-18 UNF, or for quick-coupling adapters of the service connections to the refrigerant circuit.

Quick-coupling adapter for service connections
- High-pressure side with nominal diameter 16 mm
- Low-pressure side with nominal diameter 13 mm
![]()
Note
These quick couplings are included with the air conditioning service station.

Tools you make yourself
Charging hose with connection to the workshop compressed air system
- Charging hose 5/8" - 18 UNF** (version with large inside diameter)
- Connection for workshop compressed air system** (operate only with filter and dryer for compressed air)
** Tools and materials available from specialist retailers.