Air conditioning with R134a refrigerant

Legal texts and regulations

~12min read

Laws and regulations


Note

  • The laws and regulations listed below apply in the Federal Republic of Germany. Other or additional laws or regulations may apply in other countries.
  • For other countries, obtain the sources from the responsible authorities.

The effects of climate change can now be observed worldwide. Climate protection is therefore one of the most important tasks facing humanity. However, this task presents all those involved with enormous challenges.

The so-called Kyoto Protocol defines, among other things, the global climate protection targets. In addition to reduction targets for carbon dioxide, this protocol also contains reduction targets for fluorinated greenhouse gases, e.g. for the refrigerant R134a, because of its high global warming potential.

For the automotive trade, numerous relevant laws have been enacted at European level, for example. Nationally, in addition to specifying European legislation, the Chemicals Climate Protection Ordinance (Chemikalien-Klimaschutzverordnung) came into force in the Federal Republic of Germany on 1 August 2008.

  • Regulation (EC) No. 1005/2009
  • Regulation (EC) No. 2037/2000
  • Regulation (EU) No. 517/2014
  • Regulation (EC) No. 706/2007
  • Regulation (EC) No. 307/2008
  • Directive 2006/40/EC
  • Chemicals Climate Protection Ordinance, Closed Substance Cycle and Waste Management Act (for Germany)

Maintenance and repair work on the air conditioning refrigerant circuit

All persons who carry out maintenance and repair work on motor vehicle air conditioning systems must have completed training or a training program and be qualified (proof of competence). Outside the European Community, other or additional regulations may apply.

In general, however, the following applies:

Operation, maintenance, decommissioning, take-back obligation

  • It is prohibited to allow the substances contained in products that contain refrigerants to escape into the atmosphere during operation, repair work and decommissioning, contrary to the state of the art.
  • Records of the quantities used during operation and maintenance work should be kept (refrigerant operating log, → Volkswagen InfoNet, The Service Handbook; Environmental Protection; Environmental Protection in the Trade and Service Business; Immission Control; Air-Polluting Substances – Refrigerants for Vehicle Air Conditioning Systems), so that proof of use can be presented to the responsible authority on request. Under a European Parliament regulation of 2005, a certificate of proof no longer has to be kept in the EC. Other regulations may apply in countries that are not members of the EC.
  • Distributors of the substances and preparations named in the above-mentioned regulations are obliged to take back these substances and preparations after use, or to ensure their take-back by a third party designated by them.
  • Maintenance work and decommissioning of products containing refrigerants named in the above-mentioned regulations, as well as the take-back of the substances and preparations named in these regulations, may only be carried out by persons who have the required expertise and technical equipment.

Criminal offences and administrative offences

  • Acts that violate the above-mentioned regulations and laws constitute an administrative offence. Anyone who, intentionally or negligently, during operation, maintenance or decommissioning of products containing the refrigerants in question, allows the substances they contain to escape into the atmosphere contrary to the state of the art, or who intentionally or negligently violates the valid regulations and laws mentioned above, commits an offence.

When handling compressed gases and when transferring them into other pressurized gas containers, various technical rules (e.g. TRGS 400, TRGS 402, TRGS 407, TRGS 510, TRGS 725, TRBS 3145) must be observed.


Note

The TRGS are only shown in excerpts below (scope relevant to vehicle manufacturers and workshops).

  • TRGS 400 (Hazard assessment for activities involving hazardous substances).
  • TRGS 402 (Determination and assessment of hazards from activities involving hazardous substances: inhalation exposure).
  • TRGS 407 (Activities involving gases – hazard assessment).
  • TRGS 510 (Storage of hazardous substances in portable containers).
  • TRBS 3145 / TRGS 725 (Portable pressurized gas containers – filling, holding ready, internal transport, emptying).


Note

  • The Technical Rules for Compressed Gases (TRG), the Technical Rules for Hazardous Substances (TRGS) and the Technical Rules for Operational Safety (TRBS). These reflect the state of the art in occupational safety and occupational hygiene, as well as other established ergonomic findings, for the provision and use of work equipment and for the operation of plants requiring monitoring, or for activities involving hazardous substances.
  • The technical rules listed apply in Germany. Other countries may have different regulations and rules in force.

When handling compressed gases and when transferring them into other pressurized gas containers, various technical rules (e.g. TRGS 400, TRGS 402, TRGS 407, TRGS 510, TRGS 725, TRBS 3145) must be observed.

  • General provisions for filling installations.
  • Definitions and explanations.
  • Installation and operation of filling installations.

Filling installations

  • Does not apply to vehicle manufacturers and automotive workshops.
  • Filling installations are installations for filling transportable pressure gas cylinders. The filling installation includes its operating premises and equipment.
  • Filling installations requiring a permit are installations in which compressed gases are filled into transportable pressure gas cylinders for supply to others.
  • Filling installations not requiring a permit are installations in which compressed gases are filled into transportable pressure gas cylinders for exclusive use within the same company.

Employees and their instruction

Employees must be instructed before starting their work and at recurring intervals of appropriate length, but at least once a year, on the following:

  • the special hazards when handling compressed gases,
  • the safety regulations, in particular this TRGS and TRBS,
  • the measures to take in the event of faults, damage and accidents,
  • the handling of fire extinguishing equipment and protective equipment,
  • the operation and maintenance of the filling installation, based on the operating instructions.

Filling installations may only be operated and maintained by persons who

  • have reached the age of 18,
  • have the required technical knowledge,
  • can be expected to perform their duties reliably.

Work performed under supervision may also be carried out by persons who do not meet the requirements of Number 2.1, items 1 and 2.

For filling pressure vessels, and for filling foreign cylinders, other technical rules may apply that are not mentioned here.

  • A pressure gas cylinder may only be filled with the compressed gas marked on it, and only in the quantity resulting from the pressure, weight or volume data on the cylinder (see the Pressure Vessel Ordinance).
  • For a cylinder that may optionally be used for several compressed gases, the gas to be filled and, if it is a compressed gas with tk ≥ -10 ºC (tk = critical temperature), the maximum permissible filling weight in accordance with TRGS must be marked on the cylinder in front of the filling connection.
  • Pressure gas cylinders marked with the maximum permissible filling overpressure at 15 ºC in bar must be filled by pressure (manometric filling). If the temperature during filling deviates from 15 ºC, the pressure corresponding to the deviating temperature must be determined by the filling plant; it must be ensured that the permissible filling overpressure at 15 ºC in the pressure gas cylinder is not exceeded. To detect any overfilling, random samples of the filled cylinders must be checked by pressure measurement.
  • Pressure gas cylinders marked with the maximum permissible filling quantity as net weight (filling weight, permissible weight of the filling) in kg must be filled by weight (gravimetric filling). The cylinders must be weighed during filling and, to detect any overfilling, must undergo a subsequent check weighing on a special scale. Scales used for check weighing must be calibrated.
  • Under certain conditions, gases with tk ≥ +70 ºC may be filled by volume from pressure gas cylinders with a capacity of no more than 150 l into pressure gas cylinders with a capacity of no more than 1000 cm³. For filling liquefied petroleum gas into craftsman's cylinders, the conditions of TRGS apply.
  • Different TRGS apply to vehicle cylinders:

- For gases with tk ≥ +70 ºC.

- For technical gas mixtures with tk ≥ +70 ºC.

- Liquid cryogenic compressed gases may, deviating from Number 4, be filled by volume if the filling installation and/or the cylinders are equipped with devices for measuring or limiting the volume of the filling and (except for vehicle cylinders under item 3) for measuring the temperature of the filling. When filling by volume, it must be ensured that the permissible filling weight marked on the cylinder is not exceeded. To detect any overfilling, the filled cylinders must be checked gravimetrically on a calibrated scale or, provided the compressed gases are not highly toxic, volumetrically. Volumetric checking requires appropriate devices; filling and checking devices must be independent of each other.

  • Filling and check measurements must not be carried out by the same person. Check measurements must be performed immediately after the filling process has been completed.
  • Overfilled cylinders must be safely emptied without delay down to the permitted filling quantity. The compressed gas quantity filled must then be determined again.
  • Certain parts of TRGS 407 do not apply, or apply only in a restricted way, to cylinders for liquid cryogenic compressed gases that are neither flammable nor toxic; road traffic regulations remain unaffected.
  • When filling pressure gas cylinders with gases in liquid form at filling temperatures ≤ -20 ºC, the pressure gas cylinder (if the cylinder material is not tested for temperatures ≤ -20 ºC) may only be released from the filling installation for transport once the cylinder wall has reached a temperature of ≥ +20 ºC.

Converting the R12 refrigerant circuit to an R134a refrigerant circuit and recommissioning it (retrofit)


Note

  • Due to environmental concerns and the resulting legislation, refrigerant R12 is no longer produced or available. Refrigerant R134a was developed as a replacement for refrigerant R12.
  • Air conditioning systems that were designed for refrigerant R12, however, must not simply be filled with refrigerant R134a. To ensure proper operation of the air conditioning system after conversion, various components of the refrigerant circuit must be replaced.
  • For a detailed description of the conversion procedure and notes on servicing converted refrigerant circuits, refer to → Repair Guide Air Conditioning with Refrigerant R12 Parts 2 and 3. This repair guide is only available in paper form.

Refrigerant Record Keeping

Under the Environmental Statistics Act, refrigerant consumption must be documented.

Therefore, automotive workshops must expect to provide information on refrigerant consumption to the responsible state statistical offices. It is recommended to keep records of the quantities used during operation and maintenance work (refrigerant operating log) → Volkswagen ServiceNet, Environmental Protection; HS Environmental Protection; Immission Control; Air-Polluting Substances – Refrigerants for Vehicle Air Conditioning, and to present them to the responsible authority on request.


Note

Under a regulation of the European Parliament issued in 2005, a proof-of-use sheet no longer needs to be kept within the EC. In countries that are not EC members, other regulations may apply.

Circular Economy and Waste Act


Note

  • The laws and regulations listed below apply in the Federal Republic of Germany. Other or additional laws or regulations may apply in other countries.
  • For other countries, obtain the sources from the responsible authorities.

Regulations on the handling and disposal of refrigerants and refrigerant compressor oils can be found in the Chemicals Climate Protection Ordinance and the Circular Economy and Waste Act (applies in Germany; other countries may have different regulations).

Disposal of Refrigerant and Refrigerant Compressor Oil

Refrigerant

Refrigerants intended for disposal must be filled into labeled recycling containers, observing the permissible filling quantity. For example, in Germany, refer to the Chemicals Climate Protection Ordinance and the Circular Economy and Waste Act (other countries may have different regulations).

Refrigerant Oil

Used oil disposal: Volkswagen InfoNet; General Operations; Manuals & Dealer Literature; Service Manual; 15. Environmental Protection; under General Information, follow the link "Environmental Protection in Dealer and Service Operations"; 4. Waste Disposal; 6. Disposal Routes; g. Used Oil Disposal; Refrigerant Oils

Used refrigerant oils from systems containing halogenated hydrocarbons (at least one hydrogen atom replaced by a halogen such as fluorine, chlorine, bromine or iodine) must be disposed of as special monitored waste. Mixing with other oils or substances is not permitted. Proper storage and disposal must follow national regulations. In Germany, for example, observe the Chemicals Climate Protection Ordinance and the Circular Economy and Waste Act (other countries may have different regulations).

Sources for technical rules and occupational safety and accident prevention regulations for Germany

For other countries, obtain sources from the responsible authorities.

Converting the R12 refrigerant circuit to an R134a refrigerant circuit and recommissioning it (retrofit)


Note

  • The laws and regulations listed below apply in the Federal Republic of Germany. Other or additional laws or regulations may apply in other countries.
  • For other countries, obtain the sources from the responsible authorities.
  • Due to environmental concerns and the resulting legislation, refrigerant R12 is no longer produced or available. Refrigerant R134a was developed as a replacement for refrigerant R12.
  • Air conditioning systems that were designed for refrigerant R12, however, must not simply be filled with refrigerant R134a. To ensure proper operation of the air conditioning system after conversion, various components of the refrigerant circuit must be replaced.
  • For a detailed description of the conversion procedure and notes on servicing converted refrigerant circuits, refer to → Repair Guide Air Conditioning with Refrigerant R12 Parts 2 and 3. This repair guide is only available in paper form.

Refrigerant Record Keeping


Note

  • The laws and regulations listed below apply in the Federal Republic of Germany. Other or additional laws or regulations may apply in other countries.
  • For other countries, obtain the sources from the responsible authorities.

Records of the quantities used during operation and maintenance work should be kept (refrigerant operating log, → Volkswagen ServiceNet, Environmental Protection; HS Environmental Protection; Immission Control; Air-Polluting Substances – Refrigerants for Vehicle Air Conditioning), so that proof of use can be presented to the responsible authority on request if necessary. Under a regulation of the European Parliament issued in 2005, a proof-of-use sheet no longer needs to be kept within the EC. In countries that are not EC members, other regulations may apply.

Refrigerant Circuit

Important Repair Notes for Air Conditioning Systems

  • Refrigerant R134a must not be filled into an air conditioning system designed for refrigerant R12 without modifications to the refrigerant circuit.
  • The refrigerant oils developed specifically for refrigerant circuits with R134a and R12 must not be mixed.
  • Air conditioning service units that come into contact with refrigerant may only be used for the intended refrigerant.
  • Refrigerant circuit components for refrigerant R134a are identified by labels or green stickers, or are designed (e.g., with different threads) so that they cannot be confused with components for refrigerant R12.
  • A warning label indicating the refrigerant used is attached in the engine compartment on the front end support or on the cowl panel.
  • Different refrigerants must never be mixed.


Note

When working on the refrigerant circuit, observe the information contained in the chapters "Safety Precautions" and "General Information on Working on the Refrigerant Circuit."

Converting Refrigerant Circuits from Refrigerant R12 to Refrigerant R134a

Hydrochlorofluorocarbons are no longer used as refrigerants in the automotive industry.

Convert refrigerant circuits from refrigerant R12 to refrigerant R134a and repair converted refrigerant circuits.

→ Repair Guide Air Conditioning with Refrigerant R12 Parts 2 and 3. This repair guide is only available in paper form.