B2630 Sunload Sensor
DTC DETECTION LOGIC
| DTC No. | CONSULT screen terms (Trouble diagnosis content) | DTC detection condition | |
|---|---|---|---|
| B2630 | SUNLOAD SENSOR (SHORT) (Sunload sensor) |
Diagnosis condition | When ignition switch is ON. |
| Signal (terminal) | - | ||
| Threshold | Detected calorie at sunload sensor 1395 w/m2 (1200 kcal/m2·h) or more | ||
| Diagnosis delay time | - | ||
POSSIBLE CAUSE
Sunload sensor
A/C auto amp.
Harness and connector (The sensor circuit is open or shorted.)
FAIL-SAFE
—
PERFORM DTC CONFIRMATION PROCEDURE
CONSULT
Ignition switch ON.
Select “Self Diagnostic Result” mode of “HVAC”.
Check DTC.
Is DTC detected?
YES>>Perform trouble diagnosis for the sunload sensor. Refer to DTC Diagnosis Procedure.
NO>>Inspection End.
CHECK SUNLOAD SENSOR POWER SUPPLY
Disconnect sunload sensor connector.
Ignition switch ON.
Check voltage between sunload sensor harness connector and ground.
+ − Voltage
(Approx.)Sunload sensor Connector Terminal M226 2 Ground 5 V
Is the inspection result normal?
YES>>GO TO 2.
NO>>GO TO 4.
CHECK CONTINUITY BETWEEN SUNLOAD SENSOR AND A/C AUTO AMP.
Ignition switch OFF.
Disconnect A/C auto amp. connector.
Check continuity between sunload sensor harness connector and A/C auto amp. harness connector.
Sunload sensor A/C auto amp. Continuity Connector Terminal Connector Terminal M226 3 M50 26 Yes
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair harness or connector.
CHECK SUNLOAD SENSOR
Reconnect sunload sensor connector and A/C auto amp. connector.
Check sunload sensor. Refer to Component Inspection.
Is the inspection result normal?
YES>>Replace A/C auto amp. Refer to Removal and Installation.
NO>>Replace sunload sensor. Refer to Removal and Installation.
CHECK CONTINUITY BETWEEN SUNLOAD SENSOR AND A/C AUTO AMP.
Ignition switch OFF.
Disconnect A/C auto amp. connector.
Check continuity between sunload sensor harness connector and A/C auto amp. harness connector.
Sunload sensor A/C auto amp. Continuity Connector Terminal Connector Terminal M226 2 M50 9 Yes Check continuity between sunload sensor harness connector and ground.
Sunload sensor — Continuity Connector Terminal M226 2 Ground No
Is the inspection result normal?
YES>>Replace A/C auto amp. Refer to Removal and Installation.
NO>>Repair harness or connector.
CHECK SUNLOAD SENSOR
Ignition switch ON.
Check voltage between A/C auto amp. harness connector and ground.
(+) (−) A/C auto amp. Connector Terminal M50 9 Ground 
Is the inspection result normal?
YES>>Inspection End.