Front Blower Motor
CHECK FUSE
Ignition switch OFF.
Check 15A fuses [Nos. 17 and 27, located in fuse block (J/B)].
Is the inspection result normal?
YES>>GO TO 2.
NO>>Replace the blown fuse after repairing the affected circuit.
CHECK FRONT BLOWER MOTOR POWER SUPPLY
Disconnect front blower motor connector.
Ignition switch ON.
Check voltage between front blower motor harness connector and ground.
+ − Voltage
(Approx.)Front blower motor Connector Terminal M112 4 Ground Battery voltage
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 6.
CHECK FRONT BLOWER MOTOR GROUND CIRCUIT
Ignition switch OFF.
Check continuity between front blower motor harness connector and ground.
Front blower motor — Continuity Connector Terminal M112 1 Ground Yes
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair harness or connector.
CHECK FRONT BLOWER MOTOR CONTROL SIGNAL CIRCUIT
Disconnect A/C auto amp. connector.
Check continuity between front blower motor harness connector and A/C auto amp. harness connector.
Front blower motor A/C auto amp. Continuity Connector Terminal Connector Terminal M112 3 M50 18 Yes
Is the inspection result normal?
YES>>GO TO 5.
NO>>Repair the harness or connector.
CHECK FRONT BLOWER MOTOR CONTROL SIGNAL
Reconnect front blower motor connector and A/C auto amp. connector.
Ignition switch ON.
Operate MODE switch to set air outlet to VENT.
Change fan speed from Lo to Hi, and check duty ratios between front blower motor harness connector and ground by using an oscilloscope.
T2 = Approx. 1.6 ms

Front blower motor Condition Duty ratio
(Approx.)Connector Terminal Fan speed (manual)
VENT modeM112 3 1st 25 % 2nd 31 % 3rd 37 % 4th 45 % 5th 55 % 6th 65 % 7th 77 %
Is the inspection result normal?
YES>>Replace front blower motor. Refer to Removal and Installation.
NO>>Replace A/C auto amp. Refer to Removal and Installation.
CHECK FRONT BLOWER MOTOR RELAY GROUND CIRCUIT
Ignition switch OFF.
Check continuity between fuse block (J/B) harness connector and ground.
Fuse block (J/B) — Continuity Connector Terminal M68 13R Ground Yes
Is the inspection result normal?
YES>>GO TO 7.
NO>>Repair harness or connector.
CHECK FRONT BLOWER RELAY
Check front blower motor relay. Refer to Component Inspection (Front Blower Motor Relay).
Is the inspection result normal?
YES>>Repair harness or connector between front blower motor and fuse block (J/B).
NO>>Replace front blower relay.
CHECK FRONT BLOWER MOTOR
Connect battery voltage to terminal 4 of front blower motor.
Connect ground to terminal 1 of front blower motor.
Does the front blower fan operate?
YES>>Intermittent incident. Refer to Intermittent Incident.
NO>>Replace front blower motor. Refer to Removal and Installation.
CHECK BLOWER RELAY
Ignition switch OFF.
Disconnect front blower motor relay connector.
Check continuity between front blower motor relay terminals 3 and 5 when 12 V voltage is supplied between terminals 1 and 2.

Front blower motor relay Voltage Continuity Terminals 3 5 ON Yes OFF No
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace front blower motor relay.