Driver Information & Multimedia

Power Supply and Ground Circuit

5steps
~30min
2/5difficulty
Done 0 of 5
Diagnosis Procedure

CHECK FUSE

Check that the following fuses are not blown:

Terminal No.Signal nameFuse No.Capacity
1 Battery power supply 25 10 A
2 ACC power supply 7 10 A
10 Ignition signal 29 10 A

Are the fuses blown?

YES>>

Replace the blown fuse after repairing the affected circuit.

NO>>

GO TO 2.

CHECK POWER SUPPLY CIRCUIT

  1. Ignition switch OFF.

  2. Disconnect TCU connector.

  3. Check voltage between TCU connector and ground.

    TCUGroundCondition

    Voltage

    (Approx.)
    ConnectorTerminal
    M126 1 — Ignition switch: OFF Battery voltage
    2 Ignition switch: ACC
    10 Ignition switch: ON

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace harness or connectors.

CHECK GROUND CIRCUIT

  1. Ignition switch OFF.

  2. Check continuity between TCU connector and ground.

    TCUGroundContinuity
    ConnectorTerminal
    M126 28 — Yes
    29

Is the inspection result normal?

YES>>

Inspection End.

NO>>

Repair or replace harness or connectors.