3zr-fae Battery / Charging

ECM Terminals

~1min read

ECM TERMINALS

CHECK ECM

HINT:

The standard normal voltage between each pair of ECM terminals is shown in the table below. The correct inspection conditions for each pair of terminals are also shown. Compare the inspection result with the standard normal voltage for the terminal pair shown in the Specified Conditions column. The diagram above can be used as a reference to identify the location of the ECM terminals.

Terminal No. (Symbol)

Wire Color

Terminal Description

Condition

Specified Condition

C63-59 (E1) - Body ground

W-B - Body ground

Ground

Always

Below 1 Ω

A38-1 (BATT) - C63-59 (E1)

R - W-B

Battery

(to measure battery voltage and for ECM memory)

Always

11 à 14 V

C63-61 (LIN) - Body ground

B - Body ground

LIN communication line

Ignition Switch in OFF position

(while LIN communication is stopped)

10 kΩ minimum