3zr-fae Battery / Charging

Data List / Active Test

~4min read

DATA LIST / ACTIVE TEST

DATA LIST

HINT:

The Techstream Data List allows you to read the values or status of switches, sensors, actuators and other components without removing any parts. This non-intrusive check can be very useful, since intermittent conditions or signals can be identified before parts or wiring are moved. Reading the Data List during troubleshooting saves time in diagnosis.

NOTICE:

In the table below, the values shown in the Normal Condition column are reference values. Do not rely solely on these reference values to determine whether a part is defective.

(a) Warm up the engine.

(b) Turn the ignition switch OFF.

(c) Connect the Techstream to the DLC3.

(d) Turn the ignition switch to the ON position.

(e) Turn on the Techstream.

(f) Select the following menu items: Powertrain / Engine and ECT / Data List.

(g) Check the Data List displayed on the Techstream.

HINT:

Normal condition: If no idling condition is specified, the shift lever must be in N or P, and the A/C switch and all auxiliary switches must be OFF.

Powertrain > Engine and ECT > Data List

Tester display

Item

Range

Normal Condition

Diagnostic Note

Battery Voltage

Battery voltage

Min.: 0.000 V

Max.: 65.535 V

11 to 14 V (at idle)

If the result does not meet the specification, there may be a battery voltage abnormality.

Alternator Output Duty

Generator Duty Ratio

Min.: 0.0 %

Max.: 399.9 %

Change depending on alternator output voltage

If the result does not meet the specification, suspect a malfunction in the charging system.

Alt Vol - Non Active Test

Voltage required when forced regulator control is not performed

Min.: 0.000 V

Max.: 79.998 V

13,5 à 14,4 V

(After engine start (varies depending on battery temperature or driving conditions))

If the result does not meet the specification, suspect a malfunction in the charging system.

Alt Vol - Active Test

Requests voltage when the regulator is forcibly activated

Min.: 0.000 V

Max.: 79.998 V

10,6 à 16 V

(After engine start (command voltage value request))

If the result does not meet the specification, suspect a malfunction in the charging system.

Previous Trip Alternator Max Output Time

Maximum alternator generation time during the previous driving cycle

Min.: 0 s

Max.: 65,535 s

-

-

Initial Engine Battery Minimum Voltage

Minimum battery voltage at engine start

Min.: 0.0 V

Max.: 25.5 V

-

-

HINT:

Normal condition: If no idling condition is specified, the shift lever must be in N or P, and the A/C switch and all auxiliary switches must be OFF.

ACTIVE TEST

HINT:

Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing parts. This non-intrusive functional check can be very useful, because intermittent operation can be identified before parts or wiring are moved. Performing Active Tests at the start of troubleshooting saves time during diagnosis. Data List information can be displayed during Active Tests.

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn on the Techstream.

(d) Select the following menu items: Powertrain / Engine and ECT / Active Test.

(e) Perform the Active Test by following the Techstream instructions.

Powertrain > Engine and ECT > Active Test

Tester display

Item

Control Range

Diagnostic Note

Control the Voltage of Alternator

Output voltage requested when the alternator regulator is forcibly activated

Between 10.6 and 16.0 V

Test possible after engine start