Data List / Active Test
DATA LIST / ACTIVE TEST
DATA LIST
HINT:
The Techstream Data List allows you to read the values or status of switches, sensors, actuators and other components without removing any parts. This non-intrusive check can be very useful, since intermittent conditions or signals can be identified before parts or wiring are moved. Reading the Data List during troubleshooting saves time in diagnosis.
NOTICE:
In the table below, the values shown in the Normal Condition column are reference values. Do not rely solely on these reference values to determine whether a part is defective.
(a) Warm up the engine.
(b) Turn the ignition switch OFF.
(c) Connect the Techstream to the DLC3.
(d) Turn the ignition switch to the ON position.
(e) Turn on the Techstream.
(f) Select the following menu items: Powertrain / Engine and ECT / Data List.
(g) Check the Data List displayed on the Techstream.
HINT:
Normal condition: If no idling condition is specified, the shift lever must be in N or P, and the A/C switch and all auxiliary switches must be OFF.
Powertrain > Engine and ECT > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Battery Voltage |
Battery voltage |
Min.: 0.000 V Max.: 65.535 V |
11 to 14 V (at idle) |
If the result does not meet the specification, there may be a battery voltage abnormality. |
Alternator Output Duty |
Generator Duty Ratio |
Min.: 0.0 % Max.: 399.9 % |
Change depending on alternator output voltage |
If the result does not meet the specification, suspect a malfunction in the charging system. |
Alt Vol - Non Active Test |
Voltage required when forced regulator control is not performed |
Min.: 0.000 V Max.: 79.998 V |
13,5 à 14,4 V (After engine start (varies depending on battery temperature or driving conditions)) |
If the result does not meet the specification, suspect a malfunction in the charging system. |
Alt Vol - Active Test |
Requests voltage when the regulator is forcibly activated |
Min.: 0.000 V Max.: 79.998 V |
10,6 à 16 V (After engine start (command voltage value request)) |
If the result does not meet the specification, suspect a malfunction in the charging system. |
Previous Trip Alternator Max Output Time |
Maximum alternator generation time during the previous driving cycle |
Min.: 0 s Max.: 65,535 s |
- |
- |
Initial Engine Battery Minimum Voltage |
Minimum battery voltage at engine start |
Min.: 0.0 V Max.: 25.5 V |
- |
- |
HINT:
Normal condition: If no idling condition is specified, the shift lever must be in N or P, and the A/C switch and all auxiliary switches must be OFF.
ACTIVE TEST
HINT:
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing parts. This non-intrusive functional check can be very useful, because intermittent operation can be identified before parts or wiring are moved. Performing Active Tests at the start of troubleshooting saves time during diagnosis. Data List information can be displayed during Active Tests.
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menu items: Powertrain / Engine and ECT / Active Test.
(e) Perform the Active Test by following the Techstream instructions.
Powertrain > Engine and ECT > Active TestTester display | Item | Control Range | Diagnostic Note |
|---|---|---|---|
Control the Voltage of Alternator |
Output voltage requested when the alternator regulator is forcibly activated |
Between 10.6 and 16.0 V |
Test possible after engine start |