3zr-fae Battery / Charging

Loss of Communication with Alternator (P161A)

~1min read

DESCRIPTION

The ECM and the generator assembly each detect reception errors.

A reception error of the generator assembly detected by the generator assembly is transmitted to the ECM via LIN communication. If an error occurs in the ECM or the generator assembly, the ECM determines that there is a LIN communication error and stores this DTC.

DTC No.

Detection Item

DTC Detection Condition

Suspected Area

P161A

Loss of communication with alternator

Communication stops between the ECM or the generator assembly for approximately 17 minutes or more with the ignition switch ON.

(1 trip detection logic)

  • Wire Harness and Connector
  • Generator assembly
  • ECM

WIRING DIAGRAM

PROCEDURE

  1. INSPECT CHARGING SYSTEM

(a) Check the charging system.

Click here

NG

REPAIR OR REPLACE CHARGING SYSTEM

OK
  1. INSPECT WIRE HARNESS AND CONNECTOR (ECM - GENERATOR ASSEMBLY WITH REGULATOR)

(a) Disconnect the C63 ECM connector.

(b) Disconnect the C37 connector from the generator assembly.

(c) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

C63-61 (LIN) - C37-2 (LIN)

Always

Below 1 Ω

C63-61 (LIN), C37-2 (LIN) - Body Ground

Always

10 kΩ minimum

OK

REPLACE GENERATOR ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR