Heater / Air Conditioning

Removal

~1min read

REMOVAL

PROCEDURE

1. RECOVER REFRIGERANT FROM REFRIGERANT SYSTEM (for HFC-134a (R134a))

Click here

2. RECOVER REFRIGERANT FROM REFRIGERANT SYSTEM (for HFO-1234yf (R1234yf))

Click here

3. REMOVE AIR CONDITIONING PRESSURE SENSOR (VALEO make)

(a) Disconnect the connector.

*a

Turn

*b

Hold

(b) Using a 27 mm long socket wrench, remove the air conditioning pressure sensor as shown in the illustration.

NOTICE:

Using vinyl tape, seal the openings of the disconnected parts to prevent moisture or foreign matter from entering.

4. REMOVE AIR CONDITIONING PRESSURE SENSOR (DENSO make)

(a) Disconnect the connector.

(b) Using a 27 mm long socket wrench, remove the air conditioning pressure sensor as shown in the illustration.

NOTICE:

Using vinyl tape, seal the openings of the disconnected parts to prevent moisture or foreign matter from entering.

*a

Turn

*b

Hold