Installation
INSTALLATION
PROCEDURE
1. INSTALL AIR CONDITIONING PRESSURE SENSOR (VALEO make)
(a) Remove the vinyl tape from the cooler refrigerant liquid tube A.
(b) Apply a sufficient amount of compressor oil to a new air conditioning pressure sensor and to the mating surface of the air conditioning pressure sensor.
Compressor oil:
VC100YF or equivalent
(c) Using a 27 mm long socket wrench, install the air conditioning pressure sensor as shown in the illustration. Torque: 9.8 N·m {100 kgf·cm, 87 in·lbf} |
|
(d) Connect the connector.
2. INSTALL AIR CONDITIONING PRESSURE SENSOR (Denso Manufactured)
(a) Remove the vinyl tape from the cooler refrigerant liquid tube A.
(b) Apply a sufficient amount of compressor oil to a new air conditioning pressure sensor and to the mating surface of the air conditioning pressure sensor.
Compressor oil:
ND-OIL 12 or equivalent
(c) Using a 27 mm long socket wrench, install the air conditioning pressure sensor as shown in the illustration. Torque: 10.8 N·m {110 kgf·cm, 8 ft·lbf} |
|
(d) Connect the connector.
3. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFC-134a (R134a))
Click here![]()
4. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFO-1234yf (R1234yf))
Click here![]()
5. WARM UP ENGINE (for HFC-134a (R134a))
Click here![]()
6. WARM UP ENGINE (for HFO-1234yf (R1234yf))
Click here![]()
7. CHECK FOR REFRIGERANT LEAK (for HFC-134a (R134a))
Click here![]()
8. CHECK FOR REFRIGERANT LEAK (for HFO-1234yf (R1234yf))
Click here![]()