K114 Continuously Variable Transmission

Inspection

~6min read

INSPECTION

PROCEDURE

1. INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY (without Smart Key System)

HINT:

If the following inspection results meet the specifications but a malfunction still exists, replace the shift lock control unit assembly.

(a) Check the wire harness.

(1) Disconnect the shift lock control ECU connector.

(2) Measure the voltage according to the value(s) shown in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

1 (ACC) - Body ground

Ignition Switch in ACC position

11 à 14 V

Ignition Switch in OFF position

Below 1 V

4 (IG) - Body ground

Ignition Switch in ON position

11 à 14 V

Ignition Switch in OFF position

Below 1 V

8 (STP) - Body ground

Brake pedal depressed

11 à 14 V

Brake pedal released

Below 1 V

If the result is not as specified, repair or replace the wire harness or connector.

*a

Front view of wire harness side connector

(to shift lock control ECU (shift lock control unit assembly))

(3) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

7 (E) - Body ground

Always

Below 1 Ω

If the result is not as specified, repair or replace the wire harness or connector.

*a

Front view of wire harness side connector

(to shift lock control ECU (shift lock control unit assembly))

(b) Check the key interlock solenoid operation signal.

(1) Connect the shift lock control ECU connector.

(2) Measure the voltage according to the value(s) shown in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

5 (KLS+) - Body ground

Ignition switch ACC and shift lever in P position

Below 1 V

Ignition switch ACC and shift lever in position other than P

11 à 14 V

If the result is not as specified, replace the shift lock control unit assembly.

HINT:

Do not disconnect the shift lock control ECU connector.

*a

Component with Wire Harness Connected

(shift lock control ECU (shift lock control unit assembly))

(c) Inspect the shift lock solenoid valve.

(1) Disconnect the shift lock solenoid valve connector.

(2) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

1 (SLS+) - 2 (SLS-)

Always

112 Ω

4 (P) - 3 (E2)

Shift lever in P position

10 kΩ minimum

Shift lever in position other than P

Below 1 Ω

If the result is not as specified, replace the shift lock control unit assembly.

*a

Component without wire harness connected

(Shift lock solenoid valve (shift lock control unit assembly))

2. INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY (with Smart Key System)

HINT:

If the following inspection results meet the specifications but a malfunction still exists, replace the shift lock control unit assembly.

(a) Check the wire harness.

(1) Disconnect the shift lock control ECU connector.

(2) Measure the voltage according to the value(s) shown in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

5 (IG) - Body ground

Engine switch in ON (IG) position

11 à 14 V

Engine switch in OFF position

Below 1 V

4 (STP) - Body ground

Brake pedal depressed

11 à 14 V

Brake pedal released

Below 1 V

If the result is not as specified, repair or replace the wire harness or connector.

*a

Front view of wire harness side connector

(to shift lock control ECU (shift lock control unit assembly))

(3) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

1 (E) - Body ground

Always

Below 1 Ω

If the result is not as specified, repair or replace the wire harness or connector.

*a

Front view of wire harness side connector

(to shift lock control ECU (shift lock control unit assembly))

(b) Inspect the shift lock solenoid valve.

(1) Disconnect the shift lock solenoid valve connector.

(2) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

1 (SLS+) - 2 (SLS-)

Always

112 Ω

4 (P) - 3 (E2)

Shift lever in P position

10 kΩ minimum

Shift lever in position other than P

Below 1 Ω

If the result is not as specified, replace the shift lock control unit assembly.

*a

Component without wire harness connected

(Shift lock solenoid valve (shift lock control unit assembly))

3. INSPECT TRANSMISSION CONTROL SWITCH (SHIFT LOCK CONTROL UNIT ASSEMBLY)

(a) Disconnect the shift lock control unit assembly connector.

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

1 (SFTD) - 2 (E)

Shift lever held in "-" (downshift)

Below 1 Ω

Shift lever in position other than "-"

10 kΩ minimum

3 (SFTU) - 2 (E)

Shift lever held in "+" (upshift)

Below 1 Ω

Shift lever in position other than "+"

10 kΩ minimum

If the result is not as specified, replace the shift lock control unit assembly.

*a

Component without wire harness connected

(transmission control switch (shift lock control unit assembly))