IG Signal Circuit
DESCRIPTION
This circuit detects the ignition switch ON or off condition, and sends it to the main body ECU (multiplex network body ECU).
WIRING DIAGRAM
NOTICE:
- Inspect the fuses for circuits related to this system before performing the following procedure.
- First, check for smart key system (for Start Function) DTCs, and after confirming that there is no malfunction, proceed with troubleshooting.*1
for HEV Model: Click here
.gif)
for Gasoline Model: Click here
.gif)
- Before replacing the main body ECU (multiplex network body ECU), refer to Registration.*1
- *1: w/ Smart key System
PROCEDURE
READ VALUE USING GTS
(a) Read the Data List according to the display on the GTS.
Body Electrical > Main Body > Data ListTester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
IGR Power |
Ignition switch ON signal |
OFF or ON |
OFF: Ignition switch off ON: Ignition switch ON |
- |
IGR Power
OK:
Normal conditions listed above are displayed.
| OK | PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE |
|
CHECK HARNESS AND CONNECTOR (POWER DISTRIBUTION BOX ASSEMBLY - POWER SOURCE)
(a) Disconnect the 8C and 8K power distribution box assembly connectors.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
8K-1 - Body ground |
Ignition switch off |
11 to 14 V |
8C-17 - Body ground |
Ignition switch off |
Below 1 V |
8C-17 - Body ground |
Ignition switch ON |
11 to 14 V |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK HARNESS AND CONNECTOR (POWER DISTRIBUTION BOX ASSEMBLY - BODY GROUND)
(a) Disconnect the 8B and 8C power distribution box assembly connectors.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
8B-36 - Body ground |
Always |
Below 1 Ω |
8C-41 - Body ground |
Always |
Below 1 Ω |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
INSPECT POWER DISTRIBUTION BOX ASSEMBLY
*a |
Component without harness connected (Power Distribution Box Assembly) |
- |
- |
(a) Remove the main body ECU (multiplex network body ECU) from the power distribution box assembly.
Click here ![]()
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
8B-36 - MB-13 (GND1) |
Always |
Below 1 Ω |
8C-41 - MB-14 (GND2) |
Always |
Below 1 Ω |
8K-1 - MB-27 (IGR) |
Auxiliary battery not connected to 8C-17 - 8B-36 or 8C-41 |
10 kΩ or higher |
8K-1 - MB-27 (IGR) |
Auxiliary battery positive (+) → 8C-17 Auxiliary battery negative (-) → 8B-36 or 8C-41 |
Below 1 Ω |
| OK | REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) |