Electrical System General Information

Repair kit -VAS 6410-

~5min read

Application of the repair kit -VAS 6410-

The repair kit -VAS 6410- enables optimal repair quality for vehicle electrical work. With these tools, repairs can be carried out on the contact points of wiring harnesses for bolted connections in high-current circuits (starter and charging current). The repair kit -VAS 6410- is adapted to the vehicle's construction and ensures reliable repair results and a convenient workflow.


Note

The pictures for the repair work are examples only.

Repair kit VAS 6410

VW UP. Elektrische Anlage Allgemeine Informationen

Repairing cable lugs

Required Special Tools, Test and Measuring Equipment and Auxiliary Items

  • VAG 1331


Note

  • Do not use penetrating oil, contact spray, grease or similar products. Without thread friction, the tightening torque is reached at a higher clamping force, which can exceed the torque and break the bolted connection.
  • The grey abrasive pads are suitable for light contamination and "soft surfaces". The red abrasive pads are suitable for heavy contamination and "hard surfaces".


WARNING!

Risk of injury! Observe the warnings and safety regulations!

- Disconnect the battery.

VW UP. Elektrische Anlage Allgemeine Informationen

- Loosen the cap nut and remove the cable lug from the bolted connection.

- Check the cable lug for corrosion, contamination, etc.

- Select the appropriate adapter and abrasive pad.


Note

Alternatively, the abrasive block can be used.


Caution!

Take care not to remove too much of the tin coating so that the copper is exposed. This can create a galvanic cell that corrodes a metal and leads to faulty repairs.


Note

Due to the design-related coating thickness of the tin plating, the cleaning process must be carried out in several steps, and the cable lug must be visually inspected between steps.

VW UP. Elektrische Anlage Allgemeine Informationen

- Place the adapter in the cable lug and sand off the corrosion and contamination using rotating movements.

- Check the cable lug and sand it again if necessary.

VW UP. Elektrische Anlage Allgemeine Informationen

- If necessary, remove the burr from the cable lug with the deburring tool.

- Refit the cable lug and tighten the bolt to the specified torque, → Wiring diagrams, Electrical fault finding and Component locations


Note

Good electrical contact is ensured when the bolted components are tightened to the specified torque after cleaning.

- Protect the connection with a suitable corrosion protection agent,

- Reconnect the battery.


WARNING!

Risk of injury! Observe the warnings and safety regulations!

- Re-initialise the power windows, enter the radio code, set the clock and, if necessary, recode the control modules that have fault codes stored.

VW UP. Elektrische Anlage Allgemeine Informationen

Repairing bolted connections

Required Special Tools, Test and Measuring Equipment and Auxiliary Items

  • VAG 1331


Note

  • Do not use penetrating oil, contact spray, grease or similar products. Without thread friction, the tightening torque is reached at a higher clamping force, which can exceed the torque and break the bolted connection.
  • The grey abrasive pads are suitable for light contamination and "soft surfaces". The red abrasive pads are suitable for heavy contamination and "hard surfaces".


WARNING!

Risk of injury! Observe the warnings and safety regulations!

- Disconnect the battery.

VW UP. Elektrische Anlage Allgemeine Informationen

- Loosen the cap nut and remove the cable lug from the bolted connection.

- Check the bolted connection for corrosion, contamination, etc.

- Select the correct adapter and grinding pad for the bolted connection,


Caution!

Take care not to remove too much of the tin coating so that the copper is exposed. This can create a galvanic cell that corrodes a metal and leads to faulty repairs.


Note

Due to the design-related coating thickness of the tin plating, the cleaning process must be carried out in several steps, and the cable lug must be visually inspected between steps.

VW UP. Elektrische Anlage Allgemeine Informationen

- Place the adapter on the bolted connection and grind off the corrosion and contamination using rotating movements.

- Check the bolted connection and, if necessary, grind it again.

- Refit the connection and, if necessary, the anti-rotation device, and tighten to the specified torque, → Wiring diagrams, Electrical fault finding and Component locations


Note

Good electrical contact is ensured when the bolted components are tightened to the specified torque after cleaning.

- Protect the bolted connection with a suitable corrosion protection agent.

- Reconnect the battery.


WARNING!

Risk of injury! Observe the warnings and safety regulations!

- Re-initialise the power windows, enter the radio code, set the clock and, if necessary, recode the control modules that have fault codes stored.

VW UP. Elektrische Anlage Allgemeine Informationen

Cleaning the battery terminal clamp and battery post

Required Special Tools, Test and Measuring Equipment and Auxiliary Items

  • VAG 1331


Note

Do not use penetrating oil, contact spray, grease or similar products. Without thread friction, the tightening torque is reached at a higher clamping force, which can exceed the torque and break the bolted connection.


WARNING!

Risk of injury! Observe the warnings and safety regulations!

- Disconnect the battery.

- Check the battery terminal clamp and battery post for corrosion or contamination.

VW UP. Elektrische Anlage Allgemeine Informationen

- Clean the battery terminal clamp with the wire brush of the battery post cleaner using rotating movements.

VW UP. Elektrische Anlage Allgemeine Informationen

- Clean the battery post with the underside of the battery post cleaner using rotating movements.


WARNING!

Risk of injury! Observe the warnings and safety regulations!

- Reconnect the battery and secure the battery terminals to the specified torque.


Note

Good electrical contact is ensured when the bolted components are tightened to the specified torque after cleaning.

VW UP. Elektrische Anlage Allgemeine Informationen

Corrosion protection


Caution!

Lack of corrosion protection leads to damage to the vehicle electrical system.


Note

  • All bolted connections must be tightened to the specified torque.
  • When applying corrosion protection, always use the supplied hose on the preservative can.
  • For the cold area, use preservation wax.
  • For the warm area, use cavity preservative.
  • Capillary action draws the preservative automatically into the affected areas.

- Hold the applicator nozzle under the cable lug and spray around the bolt.

VW UP. Elektrische Anlage Allgemeine Informationen

- Hold the applicator nozzle above the cable lug and spray around the bolt and the cable lug.

VW UP. Elektrische Anlage Allgemeine Informationen